My WebLink
|
Help
|
About
|
Sign Out
03
City of Pleasanton
>
CITY CLERK
>
AGENDA PACKETS
>
2019
>
101519
>
03
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/9/2019 3:53:11 PM
Creation date
10/9/2019 3:53:01 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
AGENDA REPORT
DOCUMENT DATE
10/15/2019
DESTRUCT DATE
15Y
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
20.24.450 CFC Section 6004.1.17 added — Fittings and connections. <br /> Section 6004.1.17 is added to read: <br /> 6004.1.17 Fittings and connections. Fittings and connections shall be located in a gas cabinet, <br /> exhausted enclosure, gas room or exhausted valve manifold box. <br /> Exception: Welded connections. <br /> 20.24.460 CFC Section 6004.2 amended — Indoor storage and use. <br /> Section 6004.2 is hereby amended to read: <br /> 6004.2 Indoor storage and use amended. The indoor storage or use of highly toxic, toxic and <br /> moderately toxic compressed gases shall be in accordance with Sections 6004.2.1 through <br /> 6004.2.2.10.4. <br /> 20.24.470 CFC Section 6004.2.1 amended —Applicability. <br /> Section 6004.2.1 is hereby amended to read: <br /> 6004.2.1 Applicability. The applicability of regulations governing the indoor storage and use of <br /> highly toxic, toxic and moderately toxic compressed gases shall be in accordance with Sections <br /> 6004.2.1.1 through 6004.2.1.5. <br /> 20.24.480 CFC Section 6004.2.1.1 amended — Quantities not exceeding the maximum <br /> allowable quantity per control area. <br /> Section 6004.2.1.1 is hereby amended to read: <br /> 6004.2.1.1 Quantities not exceeding the maximum allowable quantity per control area. The <br /> indoor storage or use of highly toxic and toxic compressed gases in amounts not exceeding the <br /> maximum allowable quantity per control area set forth in Table 5003.1.1(2) shall be in accordance <br /> with Sections 5001, 5003, 6001, 6004.1, 6004.2.1.4 and 6004.2.1.5. <br /> 20.24.490 CFC Section 6004.2.1.4 added — Quantities not exceeding minimum threshold <br /> quantity per control area. <br /> Section 6004.2.1.4 is added to read: <br /> 6004.2.1.4 Quantities not exceeding minimum threshold quantity per control area. The <br /> indoor storage or use of highly toxic, toxic and moderately toxic gases in amounts not exceeding <br /> the minimum threshold quantity per control area set forth in Table 6004.1 shall be in accordance <br /> with Sections 6001, and 6004.1 and Chapter 50. <br /> 20.24.500 CFC Section 6004.2.1.5 amended —Quantities exceeding minimum threshold <br /> quantity per control area. <br /> Section 6004.2.1 is added to read: <br /> 6004.2.1.5 Quantities exceeding the minimum threshold quantity per control area. The <br /> indoor storage or use of highly toxic, toxic and moderately gases in amounts exceeding the <br /> minimum threshold quantity per control area set forth in Table 6004.1 shall be in accordance with <br /> Sections 6001, 6004.1, 6004.2 and Chapter 50. <br /> Page 23 of 35 <br />
The URL can be used to link to this page
Your browser does not support the video tag.