20.24.340 CFC Section 6004.1.6 added — Maximum threshold quantity. <br /> Section 6004.1.6 is added to read: <br /> 6004.1.6 Maximum threshold quantity. Toxic gases stored or used in quantities exceeding the <br /> maximum threshold quantity in a single vessel per control area or outdoor control area or H- <br /> Occupancy shall comply with the additional requirements for highly toxic gases of Section 6004 <br /> of this code. <br /> Moderately toxic gases stored or used in quantities exceeding the maximum threshold quantity in <br /> a single vessel per control area or outdoor control area or H-Occupancy shall comply with the <br /> additional requirements for toxic gases of Section 6004 of this code. <br /> 20.24.350 CFC Section 6004.1.7 added — Reduced flow valve. <br /> Section 6004.1.7 is added to read: <br /> 6004.1.7 Reduced flow valve. All containers of materials other than lecture bottles containing <br /> highly toxic material and having a vapor pressure exceeding 29 psi shall be equipped with a <br /> reduced flow valve when available. If a reduced flow valve is not available, the container shall be <br /> used with a flow-limiting device. All flow limiting devices shall be part of the valve assembly and <br /> visible to the eye when possible; otherwise, they shall be installed as close as possible to the <br /> cylinder source. <br /> Exception: When the process use rate is approximately equal to the maximum flow rate of <br /> the cylinder/tank valve. <br /> 20.24.360 CFC Section 6004.1.8 added — Fire extinguishing systems. <br /> Section 6004.1.8 is added to read: <br /> 6004.1.8 Fire extinguishing systems. Buildings and covered exterior areas for storage and use <br /> areas of materials regulated by this Chapter shall be protected by an automatic fire sprinkler <br /> system in accordance with NFPA 13. The design of the sprinkler system for any room or area <br /> where highly toxic, toxic and moderately toxic gases are stored, handled or used shall be in <br /> accordance with Section 5004.5. <br /> 20.24.370 CFC Section 6004.1.9 added — Local gas shut off. <br /> Section 6004.1.9 is added to read: <br /> 6004.1.9 Local gas shut off. Manual activation controls shall be provided at locations near the <br /> point of use and near the source, as approved by the fire code official. The fire code official may <br /> require additional controls at other places, including, but not limited to, the entry to the building, <br /> storage or use areas, and emergency control stations. Manual activated shut-off valves shall be <br /> of a fail-safe-to-close design. <br /> 20.24.380 CFC Section 6004.1.10 added — Exhaust ventilation monitoring. <br /> Section 6004.1.10 is added to read: <br /> 6004.1.10 Exhaust ventilation monitoring. For highly toxic gases, toxic and moderately toxic <br /> gases exceeding minimum threshold quantities, a continuous monitoring system shall be provided <br /> to assure that the required exhaust ventilation rate is maintained. The system shall monitor actual <br /> air flow in the exhaust system. The monitoring system shall initiate a local alarm. The alarm shall <br /> be both visual and audible and shall be designed to provide warning both inside and outside of <br /> the interior storage, use, or handling area. <br /> Page 21 of 35 <br />
The URL can be used to link to this page
Your browser does not support the video tag.