Laserfiche WebLink
Jerry Raney <br />31 March 2008 <br />Page 2 <br />approximately 500-feet east of the UPRR rail line. The noise environment is dominated by <br />local and distant traffic noise, as well as occasional train horns. <br />We measured an average DNL of 55 dBA.3 We measured a typical maximum sound level <br />of 82 dBA for train horns. <br />RECOMMENDATIONS <br />Interior Noise Levels <br />Since the DNL noise level at the project site is below 60 dBA, no mitigation is needed to <br />meet the City's interior DNL goal of 45 dBA. <br />In order to meet the City's interior single-event noise goal of 50 dBA in bedrooms and <br />55 dBA in other habitable rooms, sound-rated windows, exterior doors and exterior walls <br />aze necessary. We have summarized the STC4 ratings necessary to achieve the City's <br />single-event interior noise goals in Table 1. <br />Table 1: Minimum STC ratinQS for windows/doors and walls <br /> Windows / <br />Lot Floor Room Eat. Door Exterior Wall <br />3 1 --- .--Living/Dinin~ Room ---"-'--- --._37 _.-..------------ 42 <br /> <br />3 <br />I <br />Kitchen .-...-..-.-..-. <br />37 42 <br />3 2 TV Room 32 42 <br />3 2 Master Bedroom 28 42 <br />3 2 Master Bathroom (No door) 37 42 <br />__ 3 __ <br />----- -- 2 Master Bathroom (With door <br />---- - 32 42 <br />------------------- <br /> <br />3 <br />2 <br />Northwest Comer Bedroom ------------- <br />37 50 <br />3 2 East Bedroom 28 42 <br />4 1 LivinB/Dining~ Room_ _ 32 42 <br />4 <br />------- 1 <br />------- Kitchen <br />-- - 32 42 <br /> <br />__ 4 <br />2 __ ------- <br />TV/Fami~Room ---------------- <br />_ 34 <br />42 <br />4 2 Master Bedroom - - <br />28 42 <br />4 2 Master Bathroom 28 42 <br />4 <br />----- <br />-- 2 <br />--_ <br />-- Northwest Comer Bedroom <br />--------- 37 50 <br />- <br />4 2 Wes[Bathroom 37 42 <br />- _ <br />4 2 North Bedroom 37 50 <br />- --6--- -__.-1....._..._ .-...-.-..------ Livin~/Dining Room .-------- 42 <br />------.... 28- <br />- <br /> <br />6 <br />2 <br />Master Bedroom ---.-._...-._ <br />---- <br />- ---- -- <br />37 50 <br />6 <br />----------- 2 <br />-------------- South Bedroom <br />------ ----------------- 37 42 <br />---- - <br /> <br />6 <br />2 <br />Southeast Corner Bedroom - <br />32 42 <br />3 During the monitoring period, there was noisy street construction occurring on Augustine Street on 16 <br />February and 19 Febmary; we have subtracted the construction noise data from our measurement results. <br />° Sound Transmission Class (STC) - Asingle-figure rating standardized by ASTM and used to rate the <br />sound insulation properties of building partitions. The STC rating is derived from laboratory measurements <br />of a particulaz building element and as such is representative of the maximum sound insulation. Increasing <br />STC ratings correspond to improved noise isolation. <br />Charles M Salter Associates Inc Sao swier street say Franrisdo caemroia saio° .ec °is ss~ o°°z Fa.: °is aw oosa <br />