d. A double check detector check valve must be <br /> installed in the portion of the system between the <br /> main line and the building. The sprinkler control <br /> valve and fire department connections must be <br /> installed on the building side of the check <br /> valves. <br /> <br /> e. The portion of the onsite system which is publicly <br /> owned must be installed in accordance with City <br /> Standard Specifications for Water Distribution <br /> Systems. <br /> <br />See Standard Drawing No. Priv-1 for a typical public onsite <br />fire system layout. <br /> <br />If the onsite system is privately owned, the following apply: <br /> <br /> a. The domestic and irrigation water services must <br /> manifold off of the fire system within the public <br /> right-of-way. <br /> <br /> b. It is the owner's responsibility to routinely test <br /> and maintain the onsite fire hydrants, valves, and <br /> other system appurtenances. <br /> <br /> c. The materials to be used for the onsite system may <br /> be as allowed in NFPA Pamphlet 24, except that PVC <br /> may not be used in the fire system. <br /> <br /> d. Easements are not necessary for any portion of the <br /> system on the building side of the water meters or <br /> the double check detector check valve. <br /> <br /> e. As when the onsite system is public, a double <br /> check detector check valve must be installed in <br /> the portion of the system between the mainline and <br /> the building. The sprinkler control valve and the <br /> FDC must be installed on the building side of the <br /> check valves. The location of the three items, <br /> however, is different with a private onsite <br /> system, and must be as shown on Standard Drawing <br /> Priv-2. <br /> <br /> f. See Standard Drawing No. Priv-2 for a typical <br /> privately owned onsite system layout. <br /> <br />For either type of system, the double check detector check <br />may be installed either above ground, or below ground in a <br />concrete vault. If below ground, clearances must be as <br /> <br /> 18 <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.