My WebLink
|
Help
|
About
|
Sign Out
16 ATTACHMENT 11
City of Pleasanton
>
CITY CLERK
>
AGENDA PACKETS
>
2008
>
050608
>
16 ATTACHMENT 11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/1/2008 12:29:35 PM
Creation date
5/1/2008 12:29:34 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
STAFF REPORTS
DOCUMENT DATE
5/6/2008
DESTRUCT DATE
15 Y
DOCUMENT NO
16 ATTACHMENT 11
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
`` 1 <br />Jl ' '~ ~ <br />~'~ <br />1 \~/~ <br />January 27, 2004 <br />CITY OF DUBLIN BUILDING 8~ SAFETY DIVISION <br />100 Civic Plaza, Dublin, California 94568 <br />John Pfund <br />7233 Regional Street <br />Dublin Ca. 94568 <br />Regarding: 7233 Regional Street <br />Revoked Occupancy Notification <br />Dear Business Owner: <br />Website: htto://www.ci.dublin.ca.us <br />Phone: (925) 833-6620 <br />Fax: (925) 833-6628 <br />G°3C~C~GOMC~[D <br />NOV 1 9 2007 <br />CITY OF PLEASANTON <br />PLANNING DEPT. <br />On January 24, 2004 an inspection was performed at 7233 Regional Street at the request of the Dublin <br />Police Department. At the time of the inspection (10:00am) numerous possible code violations were <br />observed. After reviewing the City of Dublin records for this location it was determined that your <br />property is in violation of Chapters 7.28, 7.32, 7.36, 7.40 and 7.44 of the City of Dublin Municipal <br />Code: Maintaining dangerous structures or installations is prohibited. <br />It is unlawful to maintain or use a dangerous building or structure, or dangerous electrical, plumbing or <br />mechanical installation. Specifically these violations include the following: <br />1. Suspended ceiling grid and tiles are improperly supported and missing. Missing tiles may <br />affect the performance of the suppression system Ceiling support system shall be repaired to <br />meet the current building code. Inspection of the area is required by the City of Dublin prior <br />to re-installation of the tiles. (Permit required) 1994 NFPA 13 section 4-4.1.4.1 and 2001 <br />Californian Building Code, Chapter 16 reference 1632, standard 25-2 section 25.205 <br />Structural members and 25.209 installations of components. <br />2. Locking hardware (gate clasp latch type) present at rear exit door located in the lazge room <br />adjacent to the mat area Remove latch hardware and eliminate debris/obstructions in the <br />exit pathway. 2001 California Building Code, section 1003.3.1.8. <br />3. Flammable materials (paint and other chemicals) placed next to the electrical water heater. <br />Remove materials from area to a safe location. 2001 Uniform Fire Code, section 7902.1.1. <br />4. Self-closure at rear locker room exit door not function properly. Repair and/or replace. <br />2001 California Building Code, section 1005.3.3.5. <br />5. Possible overrating and/or overloading of electrical outlets (computers) at back computer <br />room Eliminate the abundance offlexible cords (extension cords). Flexible or Extension <br />Page 1 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.