My WebLink
|
Help
|
About
|
Sign Out
ORD 1965
City of Pleasanton
>
CITY CLERK
>
ORDINANCES
>
1901 - 2000
>
ORD 1965
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2023 4:23:47 PM
Creation date
1/9/2008 11:34:53 AM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
ORDINANCES
DOCUMENT DATE
12/4/2007
DESTRUCT DATE
PERMANENT
DOCUMENT NO
ORD 1965
Tags
Ordinance
Description:
Ordinance
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
106
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3. In accordance with ASCE 31 based on the applicable performance level as shown in <br />Table 3403.5.1.1.2. <br />4. Those associated with the BSE-1 Earthquake Hazard Level defined in ASCE 41 <br />and the performance level as shown in Table 3403.5.1.1.2. Where ASCE 41 is used, <br />the design spectral response acceleration parameters S,~ and Sx, shall not be taken <br />less than 75 percent of the respective design spectral response acceleration <br />parameters SDS and SD1 defined by the California Building Code and its reference <br />standards. <br />3403.5.1.2 Wind Design. Wind design of existing buildings shall be based on the <br />procedures specified in the building code. <br />3403.5.2 Repairs to damaged buildings. Repairs to damaged buildings shall comply <br />with this section. <br />3403.5.2.1 Unsafe conditions. Regardless of the extent of structural damage, unsafe <br />conditions shall be eliminated. <br />3403.5.2.2 Substantial structural damage to vertical elements of the lateral-force- <br />resisting system. A building that has sustained substantial structural damage to the <br />vertical elements of its lateral-force-resisting system shall be evaluated and repaired in <br />accordance with the applicable provisions of Section 3403.5.2.2.1 through 3403.5.2.2.3. <br />3403.5.2.2.1 Evaluation. The building shall be evaluated by a registered design <br />professional, and the evaluation findings shall be submitted to the code official. The <br />evaluation shall establish whether the damaged building, if repaired to its pre-damage <br />state, would comply with the provisions of the building code. <br />- Wind forces for this evaluation shall be those prescribed in the building code. <br />- Seismic forces for this evaluation are permitted to be the reduced level seismic forces <br />specified in Code Section 3403.5.1.1.3. <br />3403.5.2.2.2 Extent of repair for compliant buildings. If the evaluation establishes <br />compliance of the pre-damage building in accordance with Section 3403.5.2.2.1, then <br />repairs shall be permitted that restore the building to its pre-damage state, using <br />materials and strengths that existed prior to the damage. <br />3403.5.2.2.3 Extent of repair for non-compliant buildings. If the evaluation does not <br />establish compliance of the pre-damage building in accordance with Section <br />3403.5.2.2.1, then the building shall be rehabilitated to comply with applicable <br />provisions of the building code for load combinations including wind or seismic forces. <br />Wind <br />The wind design level for the repair shall be as required by the building code in effect at <br />the time of original construction unless the damage was caused by wind, in which case <br />73 <br />
The URL can be used to link to this page
Your browser does not support the video tag.