My WebLink
|
Help
|
About
|
Sign Out
ORD 1965
City of Pleasanton
>
CITY CLERK
>
ORDINANCES
>
1901 - 2000
>
ORD 1965
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2023 4:23:47 PM
Creation date
1/9/2008 11:34:53 AM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
ORDINANCES
DOCUMENT DATE
12/4/2007
DESTRUCT DATE
PERMANENT
DOCUMENT NO
ORD 1965
Tags
Ordinance
Description:
Ordinance
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
106
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
applications listed in Section 111 regulated <br />Marshal, exterior walls shall be fire-resistanc <br />601 and 602. The fire-resistance rating of <br />exposure to fire from both sides. <br />20.08.059 -This Section is Deleted. <br />by the Office of the State Fire <br />e rated in accordance with Tables <br />exterior walls shall be rated for <br />20.08.060 Table 704.8 amended -Maximum Area of Exterior Wall Openinas. <br />Table 704.8 Maximum Area of Exterior Wall Openings of the California Building <br />Standards Code 2007 Edition, (24 C.C.R.), and including by reference the International <br />Building Code, 2006 Edition, Volumes 1 and 2 is amended to read as follows: <br />TABLE 704.8 <br />MAXIMUM AREA OF EXTERIOR WALL OPENINGS <br />CLASSIFICATION FIRE SEPARATION DISTANCE (feet) <br />OF OPENING <br /> <br /> 0 to 3rd Greater Greater Greater Greater Greater Greater Greater <br /> than 3 to than 5 to than 10 than 15 than 20 than 25 than 30 <br /> $~B 10`'`~'h to 15°e'g to 20ds to 2S°'s to 3Ods <br />Unprotected Not Not Not 15°6 25%, x596, 7096 No Limit <br /> Permitted Permitted Permitted` <br />Protected Not 2596 4596 7596 <br /> 1596 No Limit No Limit No Limit <br /> Permitted <br />For SI: 1 foot .304.8 rrun. <br />a. Values given are percentage of the area of the exterior wall. <br />b. Not used <br />c. For occupancies in Group R-3, the maximum percentage of unprotected and protected exterior wall openings shall be 2S percent. <br />d. The area of openings in an open parking structure with a fire separation distance of greater than 10 feet shall not be limited. <br />e. For occupancies in Group H-2 or H-3, unprotected openings shall not be permitted for openings with a fire separation distance of <br />15 feet or less. <br />f. For requirements for fire walls for buildings with differing roof heights, see Section 705.6.1. <br />g. The area of unprotected and protected openings is not limited for occupancies in Group R-3, with a fire separation distance greater <br />than S feet. <br />h. For special requirements for Group U occupancies, see Section 406.1.2. <br />i. Includes accessory buildings to Group R-3. <br />20.08.061 Section 704.3 amended -Buildings on the same lot. <br />Section 704.3 Buildings on the same lot of the California Building Standards <br />Code 2007 Edition, (24 C.C.R.), and including by reference the International <br />Building Code, 2006 Edition, Volumes 1 and 2 is amended to read as follows: <br />53 <br />
The URL can be used to link to this page
Your browser does not support the video tag.