s UL 11 S 3 4 3 5 3 2
<br />F2 A UL UL 37,500 ~~ ~~ 18,000 50,500 21,000 13,000
<br /> S / 1 1 1 1 1 1 1 NP
<br />H 1 A 21,000 18,500 11,000 7,000 9,500 7.000 10,500 7.500 NP
<br />H-2° s UL 3 2 1 2 1 2 1 1
<br /> A 21,000 18,500 11,000 7,000 8,500 7,000 10,500 7,500 3,000
<br />µ.3° S UL g 4 2 4 2 4 2 1
<br /> A UL 80,000 28,500 14,000 17,500 13,000 25,500 10,000 5,000
<br /> S UL 7 5 3 5 3 5 3 2
<br />H~ A UL UL 37,50D 17,500 28.500 17,500 38,000 18,000 8,500
<br />H~8 S 4 4 3 3 3 3 3 3 2
<br /> A UL UL 37,500 23,000 28,500 19,000 38,000 18,000 9,000
<br /> S UL 9 4 g 4 3 4 3 2
<br />~1 A UL 56,OOD 18,000 100pp 18,SOD 10.000 18A00 10,500 4,500
<br /> S UL 4 2 1 1 NP 1 1 NP
<br />12 / 1 2. 1 A UL UL 15,000 11,000 12,000 rP 12,000 9,500 NP
<br />~. S UL 2 NP NP NP NP NP NP NP
<br /> A UL 15,100 NP NP NP NP NP NP NP
<br /> S UL 5 3 2 3 2 3 1 1
<br />14 A UL BDSOD 26,500 13,000 23,500 13,000 25,500 18500 9,000
<br />~ s f0 9 9 2 9 2 3 9 1
<br /> A l1L 39,800 18,000 12,000 1Q0010 12,000 18,000 14,000 8,000
<br /> S UL 11 4 4 4 4 4 3 1
<br />M A UL UL 21,500 12500 18,500 12500 20,500 14,000 9,000
<br />R-1 s UL 11 4 4 4 4 4 3 2
<br /> A UL UL 24,000 18,000 24,000 18,000 2D,500 12,000 7,000
<br /> S UL 11 4 4 4 4 4 3 2
<br />~ A UL UL 24,000 1&000 ~.~ 18,000 20,500 12,OOD 7,000
<br /> S UL 11 4 4 4 4 4 3 3
<br />R-3hR~3.1 A UL UL UL UL UL UL UL UL UL
<br />~ s UL 11 4 4 4 4 4 3 2
<br /> A UL UL 24,000 18,000 24,000 18,OOD 20,500 12,000 7,000
<br /> S UL 11 4 3 3 3 4 3 1
<br />S1 A UL 48,000 ~~ 17,500 28.000 17,500 25,500 14,000 9,000
<br />S~2°j0 S UL 11 5 4 4 4 5 4 2
<br /> A UL 78,000 38,000 28,000 38,000 26,000 38,500 21,000 13,500
<br />~ S UL 5 4 2 3 2 4 9 1
<br /> A UL 35,000 19,000 8,500 14,000 8,500 18,000
<br />9,000
<br />5,500
<br />For SI: 1 foot = 304.8 mm, 1 square foot = 0.0929mZ.
<br />UL =Unlimited, NP =Not permitted.
<br />a. See the following sections for general exceptions to Table 503:
<br />I. Section 504.2, Allowable height increase due to automatic sprinkler system installation.
<br />2. Section 506.2, Allowable area increase due to street frontage.
<br />3. Section 506.3, Allowable area increase due to automatic sprinkler system installation.
<br />4. Section 507, Unlimited area buildings.
<br />b. For open parking structures, see Section 406.3.
<br />c. For private garages, see Section 406.1.
<br />d. See Section 415.5 for limitations.
<br />e. (SFM] See Section 408.1.1 for specific exceptions for one-story Type MA, MA or VA
<br />construction.
<br />20.08.033 Table 2306.4.3 amended - Attachment of Particleboard Wall
<br />sheathing.
<br />Table 2306.4.3 Attachment of Particleboard Wall sheathing of the California Building
<br />Standards Code 2007 Edition, (24 C.C.R.), and including by reference the International
<br />Building Code, 2006 Edition, Volumes 1 and 2 is amended to read as follows:
<br />37