Laserfiche WebLink
City of Pleasanton <br />Final Water Supply Assessment <br />Stoneridge Drive Specific Plan Amendment and Staples Ranch Project <br />4.0 Water Agency Background <br />5.3.4.2. Groundwater Basin Management <br />In years prior to construction of the SWP and other surface water deliveries, groundwater was the <br />sole source of water for the entire Livermore Amador Valley. The Main Basin experienced several <br />periods of extended withdrawals and subsequent recovery in normal or wet years. In the 1960's, <br />approximately 110,000 acre -feet of groundwater was extracted for supply uses; this resulted in an <br />estimated historic low of 130,000 acre -feet remaining in storage. Now, under all circumstances, this <br />historic low is considered a not -to- exceed threshold in any given year. Significant recovery of the <br />Main Basin to pre- 1960's levels was achieved in the twenty year span of 1962 to 1983. It was during <br />this era that Zone 7 initiated a series of programs to build reliability into their water supply system. <br />First, Zone 7 conducted a program of groundwater replenishment by artificially recharging via local <br />streams with imported surface water for storage in the Main Basin; secondly, Zone 7 commenced <br />using treated surface water to augment groundwater supplies; and finally, Zone 7 began regulating <br />groundwater pumping throughout their service area by contractually establishing annual <br />Independent Quotas (IQ) now known as a Groundwater Pumping Quota (GPQ) for each <br />municipality. <br />Groundwater levels in the Main Basin are routinely monitored by Zone 7 staff. Two independent <br />methods are used to estimate groundwater storage: 1) Hydrologic Inventory and 2) Nodal Water <br />Level. The Hydrologic Inventory method computes storage change each quarter from basin supply <br />and demand data. This method can also be used to forecast future water storage conditions. The <br />Nodal Water Level method computes storage from hundreds of water level measurements. <br />According to the City of Pleasanton's UWMP, the correlation between these two distinct methods <br />ensures confidence in Zone 7's ability to measure, monitor and even forecast groundwater storage <br />changes in the Main Basin." <br />Zone 7 operates the groundwater basin to maximize conjunctive use of regional water supplies. <br />Currently, the Main Basin is managed so that under non emergency conditions, including several <br />multi -year droughts, groundwater elevations do not drop below historic low levels of 130,000 AF. <br />Present day operational plans consistently maintain approximately 130,000 AF [above the historic <br />low] for extreme emergency storage at all times. <br />Under Zone 7's Basin Management Plan (Plan), in wet and normal years, groundwater is replaced <br />through artificial recharge in the Arroyo Valle stream system using imported surface water. <br />Operational plans call for seasonal storage through artificial recharge of 15,000 to 20,000 AF of <br />water within the groundwater basin. In other words, Zone 7 replaces seasonal Main Basin <br />extractions with an equal quantity of artificially recharged water. This seasonal replacement <br />program helps maintain at least 110,000 AF for "drought storage" in the Main Basin. Zone 7's <br />operational policy is to maintain the balance between the combination of natural and artificial <br />recharge and groundwater withdrawals. This preserves approximately 240,000 AF of total storage in <br />the Main Basin for drought and emergency use 110,000 AF for drought storage and 130,000 AF to <br />be used only in case of extreme emergency. The Plan allots a portion of 110,000 AF of Main Basin <br />"drought storage" for extraction in dry years to make up for any SWP shortages that may occur due <br />to hydrologic conditions or environmental constraints placed on the SWP system, such as the <br />Califomia aqueduct pump shutdown in June 2007." In terms of reliability, this amount is sufficient <br />when used in conjunction with other water supplies and [Out -of- Basin] groundwater storage in <br />11 2005 Zone 7 Water Agency Urban Water Management Plan, page 19. <br />12 City of Pleasanton letter dated June 8, 2007: Regarding the Department of Water Resources Pump Shutdown <br />June 2007 Zone 7 provided adequate water to Pleasanton by utilizing groundwater storage in addition to supplies <br />in the Del Valle Reservoir. <br />vwq.a.. INP V O, 411132.01 arpaaRanch vre rwe&doo <br />5 -12 <br />