My WebLink
|
Help
|
About
|
Sign Out
2249
City of Pleasanton
>
BOARDS AND COMMISSIONS
>
PLANNING
>
RESOLUTIONS
>
1980-1989
>
1982
>
2249
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/15/2010 2:02:15 PM
Creation date
7/30/2007 11:38:07 AM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
RESOLUTIONS
DOCUMENT DATE
12/8/1982
DOCUMENT NO
2249
DOCUMENT NAME
TRACT 5101
NOTES
VALLEY PLAZA APARTMENTS JOINT VENTURE
NOTES 2
SUBDIVIDE APPR..9 ACRE OF LAND
NOTES 3
E. OF BROOKTREE WAY
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
RES. 2249 EXHIBIT "A" 12/8/82 <br />MEMORANDUM <br />December 10, 1982 <br />T0: Planning Commission <br />FROM: Engineering Services - City Engineer <br />SUBJECT: Staff Report for Tentative Map <br />Tract 5101, Valley Plaza Townhouses <br />This development is recommended for approval subject to the <br />following conditions: <br />1. That a detailed grading and drainage plan and all <br />supporting information and design criteria be <br />submitted as part of the improvement plans for <br />the development. <br />2. That all existing wells, septic tanks or holding <br />tanks on the site be properly sealed, filled and <br />abandoned prior to the start of grading operations <br />unless Zone 7 retains specific wells for observation <br />wells, or special approval is obtained from the City <br />Engineer for temporary use of an existing well for <br />construction water. <br />3. That the haul route for all materials to and from <br />this development be approved by the City Engineer <br />prior to approval of the final map or the start of <br />any construction. <br />4. That storm drainage swales, gutters, inlets, outfalls, <br />pipes and channels not within the area of a dedicated <br />public street or public service easement be privately <br />maintained by the property owners or through an <br />association approved by the City.. <br />5. That approval of the water supply and distri- <br />bution system be withheld pending final design <br />and until the developer has demonstrated to the <br />satisfaction of the City Engineer that the proposed <br />system meets both the immediate and long range <br />requirements £or supplying water in this area. <br />
The URL can be used to link to this page
Your browser does not support the video tag.