My WebLink
|
Help
|
About
|
Sign Out
2251
City of Pleasanton
>
BOARDS AND COMMISSIONS
>
PLANNING
>
RESOLUTIONS
>
1980-1989
>
1982
>
2251
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/18/2008 2:37:12 PM
Creation date
7/30/2007 11:36:10 AM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
RESOLUTIONS
DOCUMENT DATE
12/8/1982
DOCUMENT NO
2251
DOCUMENT NAME
TRACT 5006
NOTES
KEN EARP ET AL
NOTES 2
238 LOT RESIDENTIAL SUBDIVISION PROPOSED FOR AN APPR. 29 ACRE SITE
NOTES 3
N. SIDE OF VINEYARD AVE. OPPOSITE SAUTERNE WAY
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
15. That the developer submit a dust control plan or procedure as part <br />of the improvement plans prior to approval of the final map. <br />utters, inlets, outfalls and %'~ <br />16. That storm drainage swales, g <br />channels not within the area of a dedicated public street or public <br />service easement be privately maintained by the property owners or <br />through an association approved by the City. <br />17. That approval of the water supply and distribution system be <br />withheld pending final design and until the developer has <br />demonstrated to the satisfaction of the City Engineer that the <br />proposed system meets both the immediate and long range requirements <br />for supplying water in this area. <br />18. That the developer comply with any and all applicable <br />requirements of the cross-connections control and backflow <br />prevention device programs required by the California Administrative <br />Code, Title 17. <br />19. That the developer pay the applicable Zone 7 and City connection <br />fees and the meter cost prior to Council approval of the <br />development for any water meters (irrigation meters) not directly <br />related to a building permit. <br />20. That water meters be provided consistent with the private water <br />system authorized in the affordable housing agreement for Quail <br />Creek and approved by City staff. <br />21. That approval for the number, type and location of fire hydrants ~ <br />be withheld pending final design, review by the Fire Marshal, and ~ <br />final review by the City Engineer. <br />22. That approval of the sanitary sewer system be withheld pending final <br />design and until the developer has demonstrated to the satisfaction <br />of the City Engineer that the proposed system is adequate, <br />connects to an approved point of discharge, and meets both the <br />immediate and long-range requirements of the sanitary sewer system <br />in this and all tributary areas. <br />23. That a separate sanitary sewer lateral be provided to each lot of <br />record within the development unless otherwise approved by the <br />City Engineer. <br />24. That approval of the storm drainage system be withheld pending <br />final design and until the developer has demonstrated to the satis- <br />faction of the City Engineer that the system is adequate, connects <br />to an approved point of discharge, meets any and all applicable <br />requirements of the Alameda County Flood Control District - Zone 7, <br />meets any and all applicable requirements of the Federal Emergency <br />Management Flood IIazard Program, and meets the immediate and <br />long-range requirements of this development and all upstream areas <br />intended to be drained through this tract. <br />25. That electric power distribution, gas distribution, communication <br />service, and any required alarm systems be installed underground `" <br />in a joint utility trench unless otherwise specifically approved ~ <br />by the City Engineer. <br />-2- <br />