REZONING FOR A 224 UNIT RESIDENTIAL DEVELOPMENT ON 230 ACRE SITE
NOTES 3
S. TERMINUS OF BERNAL AVE., CONCORD ST. AND BORDEAUXST.
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
16. That the elevations of the building pads on lots 21 through <br />26 shall be no higher than the adjacent lots to the north <br />on Grillo Court and Concord Street. <br />17. That the final design of all structures shall be submitted <br />to the Planning Department for approval. It is intended that <br />all structures blend with their surroundings to the maximum <br />extent practicable. Exterior building materials used shall be <br />confined to varying types of wood and some types of masonry <br />(such as slumpstone or brown brick). Colors shall be those <br />earthtones which best conform to the area. Bright obtrusive <br />colors such as white walls or red roofs shall be prohibited <br />especially on the custom home sites. <br />18. That all conditions of approval of case PUD-84-5 shall be <br />listed in the CC&Rs for the development. <br />19. That the final grading plan for the tract shall show <br />driveway access for all lots and any trees proposed to <br />be removed within the entire subject site. <br />20. That all geologic and soils reports shall be recorded with <br />the Alameda County Recorder and that all site or lot specific <br />studies shall be recorded against each parcel when completed. <br />21. That there shall be no septic tanks on the site under <br />any conditions. <br />22. That the locations of all buildings shall be such that the <br />farthest exterior wall of the structure shall be within <br />150 ft. of an appropriately designed access road or such <br />alternate measures shall be taken to provide for fire <br />suppression as determined necessary by the Fire Chief. <br />23. That there shall be a 360° ladder access to all buildings <br />on the subject property in order to enhance fire fighting <br />tactics unless this requirement is modified by the Fire <br />Chief. <br />24. That all landscaping introduced into the project shall be <br />of a fire retardant nature. <br />25. That a registered soils engineer acceptable to the City <br />shall review all on-site and off-site grading and improve- <br />ment plans for the development. When these plans are found <br />to be in accordance with his recommendations, he shall submit <br />a written statement to the City to that effect. <br />