My WebLink
|
Help
|
About
|
Sign Out
12 Exhibits
City of Pleasanton
>
CITY CLERK
>
AGENDA PACKETS
>
2007
>
022007
>
12 Exhibits
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/15/2007 3:42:28 PM
Creation date
2/15/2007 3:32:05 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
STAFF REPORTS
DOCUMENT DATE
2/20/2007
DESTRUCT DATE
15 Y
DOCUMENT NO
12 Exhibits
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
212
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />61. The project developer shall meet all requirements of the Pleasanton Fire Code <br />(Pleasanton Municipal Code, Chapter 20.24). <br /> <br />62. The building(s) covered by this approval shall be equipped with an automatic fire <br />sprinkler system. Plans and specifications for the automatic fire sprinkler system <br />shall be submitted to the Pleasanton Building and Safety Division for review and <br />approval prior to installation. The fire alarm system, including waterflow and <br />valve tamper, shall have plans and specifications submitted to Fire Prevention for <br />review and approval prior to installation. All required inspections and witnessing <br />of tests shall be completed prior to final inspection and occupancy of the <br />building(s). <br /> <br />63. The project developer shall keep the site free of fire hazards from the start of <br />construction until the final inspection. <br /> <br />64. Any project developer, business owner, or tenant storing and/or using hazardous <br />materials within a building covered by this approval, shall post National Fire <br />Protection (NFP) 704 identification on the building and/or tenancy according to <br />the City's "Hazardous Materials Identification Sign" procedures. <br /> <br />65. Prior to any construction framing, the project developer shall provide adequate <br />fire protection facilities, including, but not limited to surface roads, fire hydrants, <br />and a water supply and water flow in conformance to the City's Fire Department <br />Standards able to suppress a major fire. <br /> <br />66. All curbs located with a seven-foot, six-inch radius of a public/private fire hydrant <br />shall be painted red, unless, modified by the Fire Chief. Blue street "hydrant <br />markers" shall be installed for all fire hydrants per City of Pleasanton Standard <br />Specifications. <br /> <br />67. All portions of the buildings covered by this approval including future tenant <br />spaces shall have installed and operating, fire extinguishers with a minimum 2- <br />A:10-B:C rating. The fire extinguishers shall be located within a 75-foot radius of <br />each other. <br /> <br />Hazardous Materials USI!, Storage, and Waste Treatment: <br /> <br />68. The property or business owner shall submit a complete list of all hazardous and <br />combustible materials, including solids, liquids and gases, including biologics, to <br />the Fire Chief at least two weeks prior to submitting the building permit plan set <br />and/or the tenant improvement plan set. The list shall include all materials with <br />technical and common names, the maximum amounts to be stored, the materials' <br />Fire Code classification for the materials, whether the materials will be stored or <br />used in an open or closed environment, and the Material Safety Data Sheets for <br />all hazardous materials. <br /> <br />Page 13 of 20 <br />
The URL can be used to link to this page
Your browser does not support the video tag.