Laserfiche WebLink
46.) The homebuilder shall submit a site survey and/or record of survey and a site development plan <br /> in accordance with the provisions of Chapter 18.68 of the Municipal Code of the City of <br /> Pleasanton. These plans shall be approved by the Director of Building Inspection prior to the <br /> issuance of a building permit. The site development plan shall include all required information <br /> to design and construct site, grading, paving, drainage, and utilities. Specific items to be <br /> indicated on the site development plan necessary to construct the improvements are to be in <br /> accordance with the City of Pleasanton Private Development Design Guidelines adopted <br /> April 15, 1986. <br /> <br />47.) The paving sections for the golf course's on-site parking and drive areas shall be designed on the <br /> basis of an R-Value test and a traffic index to carry the anticipated traffic loads. This design <br /> shall be subject to the approval of the Director of Building Inspection. The minimum paving <br /> section shall be 2" A.C. on 6" of A.B. The minimum A.C. pavement slope shall be 1%. For <br /> pavement slopes of less than 1%, the surface runoff shall be carried in a concrete gutter to an <br /> acceptable point of discharge. The minimum slope for concrete gutter shall be 0.5%. <br /> <br />48.) A sanitary sewer sampling manhole shall be provided on each of the sanitary sewer lateral from <br /> each building, unless otherwise waived by the Director of Building Inspection. <br /> <br />49.) Prior to issuance of a building permit, the City shall pay the applicable Zone 7 and City <br /> connection fees and water meter cost for any water meters, including irrigation meters for the <br /> golf course, golf course related buildings, and streetscape landscaping. Additionally, the City <br /> shall pay any applicable DSRSD sewer permit fee for these improvements. Prior to issuance of a <br /> building permit, the homebuilder shall pay the applicable Zone 7 and City connection fees and <br /> water meter cost for any water meters, including irrigation meters for the individual home sites. <br /> Additionally, the homebuilder shall pay any applicable DSRSD sewer permit fee for the <br /> individual homes. <br /> <br />50.) All retaining walls higher than four feet from the top of the wall to the bottom of the footing shall <br /> be constructed of reinforced concrete or shall be an approved crib wall type. Calculations signed <br /> by a registered civil engineer shall accompany the wall plans. <br /> <br />51.) The homebuilder shall submit plot plans for each of the residential lots showing building <br /> setbacks and a topographic plan showing grading and drainage. Pad elevations, finish floor <br /> elevations, retaining walls, easements, and maximum height of the highest structure are to be <br /> indicated on the plan. Plans for custom lots are to be signed by a registered civil engineer. All <br /> residential plot plans shall show compliance with 2907(d) and 70012(d) of the Uniform Building <br /> Code. <br /> <br />52.) Property lines shall be located a minimum of two feet from the uphill side of the top of bank. <br /> <br />PUD-98-016 Conditions of Approval - City Council Page 7 3 of 14 <br /> <br /> <br />