My WebLink
|
Help
|
About
|
Sign Out
PC-93-05
City of Pleasanton
>
BOARDS AND COMMISSIONS
>
PLANNING
>
RESOLUTIONS
>
1990-1999
>
1993
>
PC-93-05
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/15/2006 9:33:42 AM
Creation date
4/27/2005 1:33:55 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
RESOLUTIONS
DOCUMENT DATE
1/27/1993
DOCUMENT NO
PC-93-05
DOCUMENT NAME
VTTM 6601
NOTES
PLEASANTON ROTARY NORTH/CITY OF PLEASANTON
NOTES 3
SUBD INTO 7 TOWNHOUSE LOTS, SE CORNER
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br />26. That approval for the number, type and location of fire <br />hydrants be withheld pending final design, review by the <br />Fire Marshal, and final review by the city Engineer. <br /> <br />27. That approval of the sanitary sewer system be withheld <br />pending final design and until the developer has <br />demonstrated to the satisfaction of the City Engineer that <br />the proposed system is adequate, connects to an approved <br />point of discharge, and meets both the immediate and long- <br />range requirements of the sanitary system in this and all <br />tributary areas. <br /> <br />28. That if a sanitary sewer lift station is installed for use <br />by the development and if it is accepted by the City for <br />maintenance and operation, an agreement shall be completed <br />between the City and the developer prior to the approval of <br />the final map to the effect that the developer will provide <br />a maintenance and operation fund for a minimum ten year <br />period. <br /> <br />29. That approval of the storm drainage system be withheld <br />pending final design and until the developer has <br />demonstrated to the satisfaction of the City Engineer that <br />the system is adequate, connects to an approved point of <br />discharge, meets any and all applicable requirements of the <br />Alameda County Flood Control District - Zone 7, meets any <br />and all applicable requirements of the Federal Emergency <br />Management Flood Hazard Program, and meets the immediate <br />and long-range requirements of this development and all <br />upstream areas intended to be drained through this <br />development. <br /> <br />30. That electric power distribution, gas distribution, <br />communication service, and any required alarm systems be <br />installed underground in a joint utility trench unless <br />otherwise specifically approved by the City Engineer. <br /> <br />31. That the developer be responsible for the installation of <br />the street lighting system serving the development. The <br />street lights shall be 70 watt, high pressure sodium vapor <br />units mounted on galvanized steel poles with poured in <br />place bases, on the LS-1C schedule per City requirements <br />and P.G.&E. standard details unless otherwise specifically <br />approved. Approval for the number, location, and type of <br />electroliers shall be withheld pending final design and <br />review by the City Engineer. <br /> <br />32. That this development provide a safe and effective <br />circulation system for bicycles and pedestrians. These <br />
The URL can be used to link to this page
Your browser does not support the video tag.