Laserfiche WebLink
<br /> <br /> <br /> <br />the Livermore-Pleasanton Fire Department prior to commencing operations. Please <br />contact the Hazardous Materials Coordinator at 925/454-2361. <br /> <br />75. FIRE HYDRANTS: Fire hydrants shall be installed at spacing not greater than 300 feet <br />in industrial and commercial developments. Fire hydrants shall be installed at spacing <br />not greater than 400 feet in residential developments. <br /> <br />76. FIRE LANE MARKING: On-site access ways, turn arounds, and internal drives shall be <br />designated as fire lanes and identified as such by red curb striping and posted with <br />signs at locations approve by the Fire Department. Signs shall be according to State <br />standards and read “No Parking – Fire Lane” and must be shown on the plans. The red <br />curb striping, sign location(s), and sign language shall be included in the building permit <br />submittal for review and approval by the Livermore-Pleasanton Fire Department prior to <br />building permit issuance. <br /> <br />The following schedule for NO PARKING signs shall apply: <br /> <br />Width Requirements <br />36 feet or greater No requirements <br />Between 28 and 36 feet Post one side <br />Between 20 and 28 feet Post both sides <br />Less than 20 feet Not permitted <br />Cul-de-Sac Not permitted <br /> <br />77. EMERGENCY VEHICLE ACCESS ROADS: Access roads shall have 13 feet, 6 inches <br />unobstructed vertical clearance, 20 feet of unobstructed width (26 feet where occupied <br />building floors exceed 30 feet height), and inside turning radius of 31 feet and outside <br />turning radius of 51 feet. Unobstructed shall mean a clear travel way, excluding parking <br />width, and designed for an emergency vehicle weight of 70,000 pounds under all <br />weather conditions. Unobstructed width shall not include the width of rolled curbs, <br />sidewalks, or non-drivable surfaces. All exterior portions of buildings must be within 200 <br />feet of an access road. Yard and parking area may be able to be located farther than <br />200 feet from access roads, depending on the specific use. <br /> <br />78. FIRE VEHICLE TURNAROUNDS: Where Fire Department vehicle access through or <br />around a site involves changes in direction or curves, inside radius of 45 feet and <br />outside radius of 55 feet shall be provided to facilitate fire truck turning radius for entry <br />and exit from the site. Dead-end access ways and internal drives shall not exceed 300 <br />feet in length and shall terminate in cul-de-sacs no less than 96 feet in diameter or <br />hammer-head (tee). Standards and options are available through the Livermore - <br />Pleasanton Fire Department, Fire Prevention Bureau. <br /> <br />79. PREMISES IDENTIFICATION: Address numbers shall be installed on the front or <br />primary entrance for all buildings. Minimum building address character size shall be 12 - <br />inch high by 1-inch stroke. In all cases address numerals shall be of contrasting <br />background and clearly visible in accordance with the Livermore-Pleasanton Fire <br />Docusign Envelope ID: 690AB28A-6A62-4ECB-9309-BC535EFC672BDocusign Envelope ID: 36B10924-68B9-4DAB-B45F-74C5F45ECB94