My WebLink
|
Help
|
About
|
Sign Out
PC-96-22
City of Pleasanton
>
BOARDS AND COMMISSIONS
>
PLANNING
>
RESOLUTIONS
>
1990-1999
>
1996
>
PC-96-22
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/15/2006 9:33:12 AM
Creation date
12/29/2004 2:41:59 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
RESOLUTIONS
DOCUMENT DATE
4/10/1996
DOCUMENT NO
PC-96-22
DOCUMENT NAME
PUD-96-05/UP-96-05
NOTES
RAYMUND VILLANUEVA/IN-N-OUT BURGER
NOTES 3
FASTFOOD RESTAURANT W/ DRIVE THRU
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br />Resolution No. PC-96-22 <br />Page 17 <br /> <br />77. The applicant shall install structural control, such as an oil/water separator, sand filter, or <br />approved equal in the parking lot to intercept and pretreat storm water prior to reaching <br />the storm drain. The design, locations, and a schedule for maintaining the separator shall <br />be submitted to the City Engineer/Director of Building Inspection for review and <br />approval prior to issuance of building permits. The structural control shall be cleaned at <br />least twice a year: once immediately prior to October I and once in January. The <br />applicant shall enter into a maintenance agreement for the oil/water separator with the <br />City. <br /> <br />78 The trash enclosure area(s) shall be completely covered. An area drain shall be installed <br />in the enclosure area which connects to the sanitary sewer. No other area shall drain into <br />the trash enclosure; a berm shall be installed to prevent such drainage if found necessary <br />by the City Engineer/Director of Building Inspection. <br /> <br />79. The applicant shall sweep or vacuum the parking lot and sidewalks a minimum of once a <br />month and shall prevent the accumulation of litter and debris on the site. Corners and <br />hard to reach areas shall be swept manually. If sidewalks and/or the parking lot are <br />pressure washed, debris must be trapped and collected to prevent entry into the storm <br />drain system. No cleaning agent may be discharged into the storm drain. If any cleaning <br />agent or degreaser is used, wash water must be collected and discharged to the sanitary <br />sewer, subject to approval of the Dublin-San Ramon Services District (DSRSD). <br /> <br />80. The restaurant shall include a contained area for cleaning mats, containers, and <br />equipment. The wash area shall be covered or shall be designed to prevent runoff onto or <br />from the area. The area shall be connected to the sanitary sewer, subject to approval by <br />DSRSD, or shall be collected in a containment area and removed regularly by a disposal <br />and recycling service. If connected to the sanitary sewer, a structural control such as a <br />sand filter or oil/ water separator shall be used, and a sign shall be posted prohibiting the <br />dumping of hazardous materials. Other methods may be used subject to the approval of <br />the Director of Building Inspection. The applicant shall instruct employees to conduct all <br />washing activities in this area. <br /> <br />{end} <br />
The URL can be used to link to this page
Your browser does not support the video tag.