<br />Resolution No. PC-97-43 <br />Page 9 <br /> <br />41. The paving sections for the on-site parking and drive areas shall be designed on the basis <br />of an R-Value test and a traffic index to carry the anticipated traffic loads. This design <br />shall be subject to the approval of the Director of Building Inspection. The minimum <br />paving section shall be 2" A.C. on 6" of A.B. The minimum A.C. pavement slope shall <br />be 1%. For pavement slopes of less than 1%, the surface runoff shall be carried in a <br />concrete gutter to an acceptable point of discharge. The minimum slope for concrete <br />gutter shall be 0.5%. <br /> <br />42. A sanitary sewer sampling manhole shall be provided on the sanitary sewer lateral from <br />the building, unless otherwise waived by the Director of Building Inspection. <br /> <br />43. Prior to issuance of a building permit, the applicants shall pay the applicable Zone 7 and <br />City connection fees and water meter cost for any water meters, including irrigation <br />meters. Additionally, the developer shall pay any applicable DSRSD sewer permit fee. <br /> <br />44. Building and situs plans are to be submitted to the Building Department on computer disk <br />in a format approved by the Director. Digitized information shall be submitted before <br />requesting a final inspection and should reflect as-built situs and architectural information <br />as approved by the Director. <br /> <br />45. If required by the Director of Building Inspection, the applicants shall submit two copies <br />of the site soils report to the Building Department. If necessary, a third party peer review <br />shall be completed at the applicants' expense prior to issuance of a grading permit. <br /> <br />Fire <br /> <br />46. The applicants shall post address numerals on the buildings so as to be plainly visible <br />from all adjoining streets or driveways during both daylight and night time hours. Tenant <br />spaces shall be identified as determined by the City. <br /> <br />47. The development shall meet all requirements of the Pleasanton Fire Code (Chapter 20.24 <br />of the Pleasanton Municipal Code). <br /> <br />48. The site shall be kept free of fire hazards from the start of construction to final inspection. <br /> <br />49. The applicants shall ensure that fire protection facilities, including all surface roads, fire <br />hydrants, and a water supply capable of furnishing the required fire flow shall be installed <br />and serviceable prior to and during the time of construction. When alternate methods of <br />protection are as approved by the Fire Chief, this requirement may be waived or <br />modified. Proposed alternative methods of fire protection shall be submitted, in writing, <br />to the Fire Chief. Work on the alternative fire protection methods shall not start without <br />the approval of the Fire Chief. <br />