My WebLink
|
Help
|
About
|
Sign Out
PC-2025-06
City of Pleasanton
>
BOARDS AND COMMISSIONS
>
PLANNING
>
RESOLUTIONS
>
2020 - PRESENT
>
2025
>
PC-2025-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/14/2025 1:35:21 PM
Creation date
4/14/2025 1:35:05 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
RESOLUTIONS
DOCUMENT DATE
3/26/2025
DESTRUCT DATE
PERMANENT
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Page 15 <br /> <br />64. FIRE HAZARDS: The project developer shall keep the site free of fire hazards from the start <br />of lumber construction until the final inspection. <br />65. FIRE CODE: All construction shall conform to the requirements of the 2022 Pleasanton Fire <br />Code and local ordinances. All required permits shall be obtained prior to work <br />commencement. <br />66. SITE SAFETY: Site safety during construction shall be in accordance with Fire Code chapter <br />33. <br />67. FIRE SPRINKLERS: Automatic fire sprinklers shall be installed in all occupancies in <br />accordance with the 2022 Pleasanton Building, Fire and Residential Codes with local <br />amendments and ordinances. <br />68. FIRE PROTECTION FACILITIES: Prior to any construction framing, the applicant shall <br />provide adequate fire protection facilities, including, but not limited to a water supply and <br />water flow in conformance to the City's Fire Department Standards able to suppress a major <br />fire. <br />69. WATER FLOW AND CONTROL VALVES: All fire sprinkler system water flow and control <br />valves shall be complete and serviceable prior to final inspection. Prior to the occupancy of <br />a building having a fire alarm system, the Fire Department shall test and witness the <br />operation of the fire alarm system. <br />70. ELECTRICAL CONDUIT: Electrical conduit shall be provided to each fire protection system <br />control valve including all valve(s) at the water connections. The Livermore-Pleasanton Fire <br />Department requires electronic supervision of all valves for automatic sprinkler systems and <br />fire protection systems. <br />71. FIRE HYDRANTS: Fire hydrants shall be installed at spacing not greater than 300 feet in <br />industrial and commercial developments. Fire hydrants shall be installed at spacing not <br />greater than 400 feet in residential developments. <br />72. FIRE LANE MARKING: On-site access ways, turnarounds, and internal drives shall be <br />designated as fire lanes and identified as such by red curb striping and posted with signs at <br />locations approve by the Fire Department. Signs shall be according to State standards and <br />read “No Parking – Fire Lane” and must be shown on the plans. The red curb striping, sign <br />location(s), and sign language shall be included in the building permit submittal for review <br />and approval by the Livermore-Pleasanton Fire Department prior to building permit <br />issuance. <br />a. The following schedule for NO PARKING signs shall apply: <br />Width Requirements <br />36 feet or greater No requirements <br />Between 28 and 36 feet Post one side <br />Between 20 and 28 feet Post both sides <br />Less than 20 feet Not permitted <br />Cul-de-Sac Not permitted <br />Docusign Envelope ID: DD265359-AEA1-4A7A-A8D3-92788E5DBFC8
The URL can be used to link to this page
Your browser does not support the video tag.