GENERAL <br />NOTES <br />SN1.0 <br />4. BOLTS: NOT LESS THAN 7 BOLT DIAMETERS FROM THE END AND 4 DIAMETERS <br />FROM THE EDGE OF THE MEMBER. BOLT HOLES 1/32 TO 1/16 INCH LARGER <br />THAN THE BOLT DIAMETER. ALL NUTS SHALL BE TIGHTENED WHEN INSTALLED <br />AND RE-TIGHTENED AT THE COMPLETION OF WORK OR BEFORE CLOSING IN. <br />THREAD PROJECTION SHALL BE 1/16 INCH MINIMUM <br /> BEYOND THE NUT. BOLTS IN SPECIFIED SLOTTED HOLES SHALL BE CENTERED <br />IN THE SLOT UON. <br />5. LAG SCREW CLEARANCE & LEAD HOLES SHALL BE BORED AS FOLLOWS: THE <br />CLEARANCE HOLE FOR THE SHANK SHALL HAVE THE SAME DIAMETER AS THE <br />SHANK, AND THE SAME DEPTH OF PENETRATION AS THE LENGTH OF <br />UNTHREADED SHANK. THE LEAD HOLE FOR THE THREADED PORTION SHALL <br />HAVE A DIAMETER EQUAL TO 60% TO 75% OF THE SHANK DIAMETER AND A <br />LENGTH EQUAL TO AT LEAST THE LENGTH OF THE THREADED PORTION. <br />6. SQUARE STEEL PLATE WASHERS (PW): ANCHOR BOLTS, BOLTS, LAGS AND <br />NUTS, NOTED PW, SHALL BE SQUARE STEEL PLATE WASHERS: <br /> BOLT DIAM THICKNESS SIZE <br /> (IN) (IN) (IN) <br /> 1/2 1/4 3 X 3 <br /> 5/8 1/4 3 X 3 <br /> 3/4 5/16 3 X 3 <br /> 7/8 5/16 3 X 3 <br /> 1 3/8 3 1/2 X 3 1/2 <br />7. CUT STEEL WASHERS: FOR BOLTS, LAGS AND NUTS, UON. <br />8. FRAMING CONNECTORS: PER MANUFACTURER'S APPROVED PRODUCT <br />EVALUATION REPORTS ICC APPROVED AND INSTALLED ACCORDINGLY. SIZE <br />AND NUMBER OF NAILS TO BE MAXIMUM SPECIFIED BY THE MANUFACTURER <br />UON. <br />9. NAILED/SCREWED HOLD DOWN ANCHORS: INSTALL PER MANUFACTURER'S <br />APPROVED ICC PRODUCT EVALUATION REPORT. INSTALL HOLD DOWNS 1/2 <br />INCH MINIMUM ABOVE THE PLATE TO ALLOW FOR TIGHTENING ANCHOR BOLT. <br />THE HOLD DOWN SHALL BE INSTALLED TIGHT TO THE HOLD DOWN POST <br />WITHOUT FILLERS OR DAPPING. DO NOT BEND HOLD DOWN ANCHORS. <br />10. BOLTED HOLD DOWN ANCHORS: INSTALL PER MANUFACTURER'S APPROVED <br />ICC PRODUCT EVALUATION REPORT. INSTALL HOLD DOWNS 1/2 INCH MINIMUM <br />ABOVE THE PLATE TO ALLOW FOR TIGHTENING ANCHOR BOLT. TIGHTEN HOLD <br />DOWN ANCHOR BEFORE TIGHTENING POST BOLTS. USE EXTRA CARE IN <br />BORING THE POST BOLT HOLES (1/32 TO 1/16 LARGER THAN THE BOLT <br />DIAMETER). THE HOLD DOWN SHALL BE INSTALLED TIGHT TO THE <br /> HOLD DOWN POST WITHOUT FILLERS OR DAPPING. THE POST BOLTS SHALL <br />NOT BE COUNTERSUNK INTO THE HOLD DOWN POST UON. DO NOT BEND HOLD <br />DOWN ANCHORS. <br />11. PRESERVATIVE TREATED WOOD: WOOD EXPOSED TO THE WEATHER; <br />FOUNDATION PLATES ON CONCRETE SLABS, FOUNDATIONS WHICH ARE IN <br />DIRECT CONTACT WITH EARTH SHALL BE TREATED WOOD WITH PRESERVATIVE <br />RETENTION AS REQUIRED FOR USE. NEWLY EXPOSED SURFACES RESULTING <br />FROM FIELD CUTTING, BORING OR HANDLING SHALL BE FIELD TREATED IN <br />ACCORDANCE WITH AWPA M-4. <br />12. TOP PLATES: TWO PIECES, SAME SIZE AS STUDS, STAGGER SPLICE 4'-0" <br />MINIMUM. CENTER SPLICES OVER STUDS. SPLICE WITH 12-16d MINIMUM UON. <br />13. FULL-DEPTH SOLID BLOCKING OR CROSS BRACING: INSTALLED AT INTERVALS <br />NOT EXCEEDING 8 FEET FOR ALL JOISTS AND RAFTERS 2x12 AND DEEPER. <br />14. SOLID BLOCKING: TWO INCH FULL WIDTH BLOCKING (FIRE STOPS) IN <br />CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED <br />SPACES, AT THE CEILING AND FLOOR LEVELS AND AT 10-FOOT INTERVALS <br />BOTH VERTICAL AND HORIZONTAL. <br />15. CUTTING AND NOTCHING: DO NOT CUT, BORE, COUNTERSINK OR NOTCH <br />WOOD MEMBERS EXCEPT WHERE SHOWN IN THE DETAILS. HOLES THROUGH <br />PLATES, STUDS AND DOUBLE PLATES IN WALLS SHALL FOLLOW DETAIL 5/SD1.0, <br />THE MEMBER WIDTH AND SHALL BE LOCATED IN THE CENTER OF THE MEMBER. <br />16. PARTITIONS: DOUBLE JOISTS UNDER PARTITIONS PARALLEL TO JOISTS AND <br />PROVIDE SOLID BLOCKING UNDER PARTITIONS PERPENDICULAR TO JOISTS. <br />17. END SUPPORT: ROOF AND FLOOR JOISTS OVER 4 INCHES DEEP SHALL HAVE <br />THEIR ENDS HELD IN POSITION WITH EITHER: <br /> FULL DEPTH SOLID BLOCKING; <br /> NAILED BRIDGING; <br /> NAILING OR BOLTING TO OTHER FRAMING MEMBERS; OR <br /> APPROVED JOIST HANGERS. <br />18. HOT DIPPED ZINC-COATED GALVANIZING: ALL EXPOSED STEEL TIMBER <br />HARDWARE, FASTENERS AND CONNECTORS. <br />19. FASTENERS FOR PRESERVATIVE TREATED WOOD SHALL BE OF HOT DIPPED <br />ZINC-COATED GALVANIZED STEEL <br />GENERAL REQUIREMENTS <br />1.VERIFICATION: VERIFY ALL DIMENSIONS, ELEVATIONS AND SITE CONDITIONS <br />BEFORE STARTING WORK. NOTIFY THE ENGINEER IMMEDIATELY OF ANY <br />DISCREPANCIES. <br />2. CONFLICTS: NOTES AND DETAILS ON THE DRAWINGS TAKE PRECEDENCE <br />OVER THE GENERAL NOTES AND TYPICAL DETAILS IN CASE OF CONFLICT. <br />3.SUBSTITUTIONS: PROVIDE MANUFACTURER'S APPROVED PRODUCT <br />EVALUATION REPORTS ICBO REPORTS AND A LIST OF ALL PROPOSED <br />SUBSTITUTIONS TO THE ENGINEER FOR REVIEW AND WRITTEN APPROVAL <br />BEFORE FABRICATION. <br />4.SIMILAR WORK: WHERE CONSTRUCTION DETAILS ARE NOT SHOWN OR <br />NOTED FOR ANY PART OF THE WORK, SUCH DETAILS SHALL BE THE SAME AS <br />FOR SIMILAR WORK SHOWN ON THE DRAWINGS. <br />5. PIPES, DUCTS, SLEEVES, CHASES, ETC.: SHALL NOT BE PLACED IN SLABS, <br />BEAMS, OR WALLS UNLESS SPECIFICALLY SHOWN OR NOTED NOR SHALL ANY <br />STRUCTURAL MEMBER BE CUT FOR PIPES, DUCTS, ETC., UNLESS <br />SPECIFICALLY SHOWN. OBTAIN PRIOR WRITTEN APPROVAL FOR INSTALLATION <br />OF ANY ADDITIONAL PIPES, DUCTS, ETC. <br />6. EXCAVATIONS: LOCATE AND PROTECT UNDERGROUND OR CONCEALED <br /> CONDUIT, PLUMBING OR OTHER UTILITIES WHERE NEW WORK IS BEING <br /> PERFORMED. <br />7.CONSTRUCTION LOADS: MATERIALS SHALL BE EVENLY DISTRIBUTED IF <br />PLACED ON FRAMED FLOORS OR ROOFS. LOADS SHALL NOT EXCEED THE <br />ALLOWABLE LOADING FOR THE SUPPORTING MEMBERS AND THEIR <br />CONNECTIONS. <br />8.CONSTRUCTION METHODS AND PROJECT SAFETY: THE CONTRACT <br />DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE AND <br />DO NOT INDICATE METHODS, PROCEDURES OR SEQUENCE OF <br />CONSTRUCTION. TAKE NECESSARY PRECAUTIONS TO MAINTAIN AND INSURE <br />THE INTEGRITY OF THE STRUCTURE DURING CONSTRUCTION. NEITHER THE <br />OWNER NOR ARCHITECT/ENGINEER WILL ENFORCE SAFETY MEASURES OR <br />REGULATIONS. CONTRACTOR SHALL DESIGN, CONSTRUCT AND MAINTAIN ALL <br />SAFETY DEVICES, INCLUDING SHORING AND BRACING, AND SHALL BE SOLELY <br />RESPONSIBLE FOR CONFORMING TO ALL LOCAL, STATE AND FEDERAL SAFETY <br />AND HEALTH STANDARDS, LAWS AND REGULATIONS. <br />9. CHANGES TO THE DRAWINGS: OBTAIN PRIOR WRITTEN APPROVAL. <br />REINFORCED CONCRETE <br />1. MATERIALS: <br /> CEMENT....................ASTM C-150 TYPE II <br /> AGGREGATE..............ASTM C-33 STANDARD WEIGHT <br /> REINFORCEMENT.......ASTM A-615 GRADE 60 TYPICAL <br /> ANCHOR BOLTS........ASTM A-307 HOOKED ANCHOR BOLTS <br /> ANCHOR BOLTS........ASTM A-307 HEADED MACHINE BOLTS <br />2. CONCRETE STRENGTHS: THE CONCRETE STRENGTHS SHOWN IN THE <br /> FOLLOWING TABLE ARE THE MINIMUM COMPRESSIVE STRENGTHS AT 28 <br />DAYS; AND THE AGGREGATE (AGG) SHOWN IS THE MAXIMUM SIZE. CONCRETE <br />SHALL BE STANDARD WEIGHT CONCRETE (145 PCF). <br /> ITEM OF STRENGTH AGG SLUMP <br /> CONSTRUCTION (PSI) (IN) (IN) <br /> FOUNDATIONS........................2,500 1 1/2 4 <br /> POUR IN PLACE WALL............2,500 1 1/2 4 <br /> SLABS-ON-GRADE..................2,500 1 4 <br /> (DESIGN STRENGTH BASED ON 2,500 PSI NO SPECIAL INSPECTION IS <br />PROVIDED) <br />3. REINFORCEMENT: <br /> A) DETAILING, FABRICATION AND PLACING: SHALL CONFORM TO AND ACI 318. <br /> B) MINIMUM CONCRETE COVER: <br /> CAST AGAINST & EXPOSED TO EARTH ......................3" <br /> EXPOSED TO EARTH OR WEATHER .............................2" <br /> NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND: <br /> SLABS, WALLS, JOISTS ...............................................3/4" <br /> BEAMS, COLUMNS (TIES, STIRRUPS, SPIRALS)........1-1/2" <br /> C) CHAIRS, SPACERS AND SAND PLATES: AS REQUIRED TO MAINTAIN <br /> CONCRETE COVER. <br /> D) VERTICAL REINFORCEMENT: SHALL BE DOWELED TO SUPPORTING <br /> MEMBERS WITH THE SAME SIZE AND SPACING OF REINFORCEMENT AS <br />SHOWN IN THE DRAWINGS AND GENERAL NOTES. <br /> E) SPACING: CLEAR DISTANCE BETWEEN PARALLEL REINFORCEMENT IN A <br />LAYER SHALL NOT BE LESS THAN 1-1/2 TIMES THE NOMINAL DIAMETER OF <br />THE REINFORCEMENT, OR 1-1/3 TIMES MAXIMUM SIZE AGGREGATE, NOR <br />LESS THAN 1-1/2". <br /> F) TACK WELDING, WELDING, HEATING OR CUTTING OF BARS: NOT <br />PERMITTED U.O.N. <br /> G) SLAB CORNERS: PROVIDE 2-#4 X 4'-0" AT RE-ENTRANT CORNERS AND <br />EACH CORNER OF RECTANGULAR HOLES IN SLABS. PLACE BARS <br />DIAGONALLY. <br /> H) SPLICES (STANDARD LAPS): LAP SPLICE PER DETAIL 1/SD1.0. STAGGER <br />BOTTOM SPLICES AT LEAST 5'-0" FROM SPLICES IN OTHER BOTTOM <br />EINFORCEMENT. STAGGER SPLICES FOR TOP REINFORCEMENT SIMILARLY. <br />4. ANCHOR BOLTS, DOWELS AND HOLD DOWN ANCHORS: SECURELY HELD IN <br />PLACE PRIOR TO FOUNDATION INSPECTION BY THE BUILDING OFFICIAL AND <br />OBSERVATION BY THE ENGINEER. <br />5. PIPES, SLEEVES AND DUCTS: NOT TO BE PLACED IN WALLS, BEAMS, SLABS, <br />FOOTINGS OR COLUMNS UNLESS SPECIFICALLY DETAILED. <br />6. CHAMFER: 3/4 INCH ON EXPOSED CORNERS. <br />7. ADMIXTURES: REVIEWED BY THE ENGINEER. CALCIUM CHLORIDE OR ADDED <br />CHLORIDES ARE NOT PERMITTED. <br />8. CONSTRUCTION JOINTS: ACI 117.9 & 6.4, 1/4 INCH AMPLITUDE MINIMUM OR <br />EYED JOINTS PER PLAN. LOCATION OF JOINTS TO BE REVIEWED BY THE <br />NGINEER. WAIT 48 HOURS BETWEEN POURS. <br />9. SLAB-ON-GRADE JOINTS: LOCATION OF ALL CONSTRUCTION, CONTROL AND <br />WEAKENED PLANE JOINTS NOT SPECIFICALLY INDICATED ON THE DRAWINGS <br />SHALL BE REVIEWED BY THE ENGINEER PRIOR TO THE PLACING OF <br />REINFORCEMENT. MAXIMUM SPACING 15 FEET ON CENTER. <br />10. ACTUAL DIMENSIONS: SLAB, WALL, BEAM AND COLUMN DIMENSIONS <br /> SHOWN ARE ACTUAL DIMENSIONS NOT NOMINAL DIMENSIONS (i.e. A 4 INCH <br /> SLAB IS 4 INCHES THICK, NOT 3-1/2 INCHES.) <br />11. CONCRETE CURING: ACI 318 <br />12. VIBRATION: ALL CONCRETE SHALL BE CONSOLIDATED WITH MECHANICAL <br />VIBRATORS. <br />WOOD <br />1.GRADE STAMPED DOUGLAS FIR/LARCH (SEE LUMBER GRADES). <br />2.NAILS: COMMON WIRE UNLESS OTHERWISE NOTED. EDGE SEE NAILING <br />NOTE BELOW. <br />3.THE SPACING CENTER TO CENTER OF NAILS IN THE DIRECTION OF STRESS <br />4.SHALL NOT BE LESS THAN THE REQUIRED PENETRATION. HOLES FOR NAILS, <br />WHERE NECESSARY TO PREVENT SPLITTING, SHALL BE BORED TO A IAMETER <br />SMALLER THAN THAT OF THE NAIL. <br />5.ANCHOR BOLTS (FOUNDATION ANCHOR BOLTS): PROVIDE 5/8 INCH <br />DIAMETER ANCHOR OR MACHINE BOLTS WITH A MINIMUM OF 7 INCHES <br />EMBEDMENT INTO THE CONCRETE AND WITHIN 12 INCHES OF EACH END OF <br />EACH PLATE. SPACE ANCHORS AT 48 INCHES ON CENTER U.O.N. ANCHORS <br />SHALL BE LOCATED A MAXIMUM OF 2 INCHES FROM THE FACE OF STUD <br />RECEIVING WOOD STRUCTURAL PANELS. ANCHOR BOLT HOLES 1/32 TO 1/16 <br />INCH LARGER THAN THE ANCHOR BOLT DIAMETER. HOLES MORE THAN 1/16 <br />INCH LARGER THAN THE ANCHOR BOLT SHALL BE EPOXY FILLED UNDER THE <br />CONTINUOUS SUPERVISION OF A LICENSED SPECIAL INSPECTOR. <br />SHEET INDEX <br />PROJECT DESIGN DATA <br />GOVERNING CODE: 2022 CALIFORNIA BUILDING CODE (CBC). <br />STRUCTURAL DESIGN LOADS: <br />1. ROOF LOADS: <br /> DEAD LOAD...................................... 15 PSF <br /> LIVE LOAD ....................................... 20 PSF <br />2. CEILING LOADS: (ATTICS WITHOUT STORAGE) <br /> DEAD LOAD......................................... 5 PSF <br /> LIVE LOAD ....................................... 10 PSF <br />3. FLOOR LOADS: <br /> DEAD LOAD....................................... 15 PSF <br /> LIVE LOAD ........................................ 40 PSF <br />4. DECK LOADS: <br /> DEAD LOAD....................................... 15 PSF <br /> LIVE LOAD ........................................ 60 PSF <br />WIND DESIGN <br /> 1. WIND SPEED 92 MPH RISK CATEGORY II, <br /> EXPOSURE C, WIND PRESSURE MIN 16 PSF USED <br /> Kh=0.85, Kzt=1, Kd=0.25, I=1 <br />SEISMIC DESIGN <br /> 1. SEISMIC BASE SHEAR FOR LIGHT-FRAME WALLS SHEATHED WITH WOOD <br /> STRUCTURAL SYSTEM = 0.210W (ALLOWABLE STRESS DESIGN) <br /> RISK CATEGORY: II SS = 1.873 S1 = 0.688 CS=0.231 <br /> SEISMIC DESIGN CATEGORY: D SDS = 1.498 SD1 = 0.780 ρ =1.3 <br /> FA = 1.2 FV= 1.0 R= 6.5 (LIGHT-FRAME WALLS SYSTEM) <br />FOUNDATION <br /> 1. FOUNDATION MATERIAL: SEE REINFORCED CONCRETE <br /> 2. MINIMUM FOUNDED DEPTH & WIDTH OF FOOTINGS: <br /> BELOW ROUGH PAD GRADE....................................................18" <br /> BELOW LOWEST ADJACENT FINISHED GRADE.....................18" <br /> WIDTH.................................................................................12" MIN. <br /> 3. BASE OF FOOTINGS & SLABS: SEE PLAN <br /> 4. ALLOWABLE SOIL PRESSURES: <br /> DL + LL LOAD........................................................................1,500 PSF <br /> ALL LOAD (WIND/SEISMIC) FORCES..................................2,000 PSF <br /> 5. ROOF AND AREA DRAINAGE: SHALL BE DIRECTED AWAY FROM THE <br /> FOUNDATIONS. <br /> 6. BACK FILL: EXCAVATIONS SHALL BE PROPERLY BACKFILLED. BACK FILL FOR <br /> WALLS SHALL BE PERVIOUS MATERIAL. DO NOT PLACE BACK FILL BEHIND <br /> WALLS BEFORE THEY HAVE ATTAINED THEIR DESIGN STRENGTH. SHORE AND <br /> PROTECT WALLS FROM LATERAL LOADS UNTIL THE SUPPORTING MEMBERS <br /> ARE IN PLACE HAVE DEVELOPED SPECIFIED STRENGTHS. <br />SPECIAL INSPECTION REQUIREMENTS <br />SPECIAL INSPECTION REQUIREMENTS <br />1.SPECIAL INSPECTION AGENCY EMPLOYED BY THE OWNER. <br />2.REPORTS: PREPARED AND SIGNED BY THE INSPECTOR, SUBMITTED TO THE <br />BUILDING OFFICIAL AND THE ENGINEER. ALL DISCREPANCIES SHALL BE <br />BROUGHT TO THE IMMEDIATE ATTENTION OF THE CONTRACTOR FOR <br />CORRECTION; THEN, IF NOT CORRECTED, TO THE BUILDING OFFICIAL AND THE <br />ENGINEER. <br />3.CERTIFICATION: INSPECTOR MUST BE CITYCERTIFIED BY THE BUILDING <br />OFFICIAL TO PERFORM THE TYPES OF INSPECTIONS SPECIFIED. <br />4.RESPONSIBILITY: IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO <br />INFORM THE SPECIAL INSPECTOR OR INSPECTION AGENCY PRIOR TO <br />PERFORMING ANY WORK THAT REQUIRESSPECIAL INSPECTION. <br />5.SPECIAL INSPECTIONS REQUIRED FOR THE FOLLOWING ITEM.: <br /> (A) EPOXY ANCHOR OR EXPANSION ANCHOR INSTALL INTO EXISTING CONCRETE <br /> SLAB OR FOOTING <br />NAILING <br />1. ALL NAILING SHALL BE COMMON WIRE NAILS AND FOLLOW THIS TABLE: <br /> SIZE DIAMETER WIRE PENETRATION <br /> PENNY INCHES GAGE INCHES <br /> 8d 0.134 10-1/4 1-5/8 <br /> 10d 0.148 9 1-7/8 <br /> 16d 0.165 8 2 <br /> 20d 0.203 6 2-3/8 <br />PENETRATION IS MEASURED INTO THE PIECE RECEIVING THE NAIL POINT. 1-1/2 <br />INCHES OF PENETRATION FOR 10d AND 16d NAILS IS ACCEPTABLE FOR TOP <br />PLATES AND DOUBLED 2X MEMBERS. WHERE THE NAIL PENETRATION WILL BE <br />LESS THAN SPECIFIED, INCREASE NAIL LENGTH (SIZE) TO OBTAIN THE <br />PENETRATION REQUIRED FOR THE NAIL SPECIFIED. <br />2. FASTENER SCHEDULE FOR STRUCTURAL MEMBERS - THE CONNECTIONS <br />LISTED ARE THE MINIMUM PERMISSIBLE. USE COMMON WIRE NAILS FOR ALL <br />NAILED CONNECTIONS. WHERE POSSIBLE, NAILS DRIVEN PERPENDICULAR TO <br />THE GRAIN SHALL BE USED INSTEAD OF TOE NAILS. SEE THE DRAWINGS FOR <br />ADDITIONAL NAILING REQUIREMENTS. <br />ROOF <br />1. CL'G. JOIST/RAFTER/TRUSS TO TOP PLATE/OTHER FRAMING BELOW, EACH <br />END, TOE NAIL .............................................................................................................3-8d <br />BLOCKING (NOT AT THE WALL TOP PLATE) TO RAFTER OR TRUSS,EACH END, <br />TOENAIL .......................................................................................................................2-8d <br />BLOCKING (NOT AT THE WALL TOP PLATE) TO RAFTER OR TRUSS,END NAIL ..... <br />......................................................................................................................................2-16d <br />FLAT BLOCKING TO TRUSS AND WEB FILLER, FACE NAIL ...................14d @ 6" O.C. <br />1.CL'G. JOIST TO TOP PLATE, EACH JOIST, TOENAIL...........................................3-8d <br />2.CL'G. JOIST LAPS OVER PARTITIONS(NO THRUST),FACE NAIL.....................3-16d <br />3.CL'G. JOIST ATTACHED TO PARALLEL RAFTER(HEEL JOINT), FACE NAIL PER <br />DETAIL <br />4.COLLAR TIE TO RAFTER,FACE NAIL ..................................................................3-10d <br />5.RAFTER OR ROOF TRUSS TO TOP PLATE,TOENAIL........................................3-10d <br />6.ROOF FATHERS TO RIDGE VALLEY OR HIP RAFTERS OR RIDGE BOARD,END <br />NAIL .............................................................................................................................2-16d <br />ROOF FATHERS TO RIDGE VALLEY OR HIP RAFTERS OR RIDGE BOARD, TOENAIL <br />......................................................................................................................................3-10d <br />WALL <br />1.STUD TO STUD (NOT AT BRACED WALL PANELS),FACE NAIL ........16d @24" O.C. <br />2.STUD TO STUD & ABUTTING STUDS AT INTERSECTING WALL CORNER, FACE <br />NAIL ..............................................................................................................16d @16" O.C. <br />3.BUILT-UP HEADER(2" TO 2" HEADER),EACH EDGE, FACE NAIL.......16d @16"O.C. <br />4.CONTINUOUS HEADER TO STUD,TOENAIL ........................................................4-8d <br />5.TOP PLATE TO TOP PLATE,FACE NAIL................................................16d @16"O.C. <br />6.TOP PLATE TO TOP PLATE(AT END JOISTS),EACH SIDE OF END JOINT, FACE <br />NAIL..............................................................................................................................8-16d <br />7.BOTTOM PLATE TO JOIST, RIM JOIST, BAND JOIST OR BLOCKING (NOT AT <br />BRACED WALL PANELS),FACE NAIL.........................................................16d @16"O.C. <br />8.BOTTOM PLATE TO JOIST, RIM JOIST, BAND JOIST OR BLOCKING ),FACE NAIL <br />....................................................................................................................2-16d @16"O.C. <br />9.STUD TO TOP OR BOTTOM PLATE,TOENAIL......................................................4-8d <br />10.STUD TO TOP OR BOTTOM PLATE,END NAIL...................................................2-16d <br />11.TOP PLATES,LAPS AT CORNERS AND INTERSECTIONS,FACE NAIL............2-16d <br />12.1" BRACE TO EACH STUD AND PLATE,FACE NAIL.............................................2-8d <br />13.1"x6" SHEATHING TO EACH BEARING,FACE NAIL..............................................2-8d <br />14.1"x8" AND WIDER SHEATHING TO EACH BEARING,FACE NAIL........................3-8d <br />FLOOR <br />1.JOIST TO SILL,TOP PLATE OR GIRDER,TOENAIL..............................................3-8d <br />2.RIM /BAND JOIST/ BLK'G TO TOP PLATE/SILL/OTHER FRAMING BELOW, <br />TOENAIL ........................................................................................................8d @ 6" O.C. <br />3.1"X6" SUBFLOOR OR LESS TO EACH JOIST,FACE NAIL....................................2-8d <br />4.2" SUBFLOOR TO JOIST OR GRIDER,FACE NAIL..............................................2-16d <br />5.2"PLANKS(PLANK & BEAM - FLOOR&ROOF),EACH BEATING,FACE NAL.......2-16d <br />6.BUILT-UP GIRDERS AND BEAM,2" LUMBER LAYERS,FACE NAIL AT TOP AND <br />BOTTOM STAGGERED ON OPPOSITE SIDES.........................................20d @32" O.C. <br />BUILT-UP GIRDERS AND BEAM,2" LUMBER LAYERS,EACH SPLICE ,FACE NAIL <br />................................................................................................................................2-20d <br />7.LEDGER STRIP SUPPORTING JOISTS OR RAFTERS,EACH JOIST OR RAFTER, <br />FACE NAIL .................................................................................................................3-16d <br />8.JOIST TO BAND JOIST OR RIM JOIST,END NAIL...............................................3-16d <br />9.BRIDGING OR BLOCKING TO JOIST,RAFTER OR TRUSS,EACH END, TOENAIL <br />.......................................................................................................................................2-8d <br />LUMBER GRADES DOUGLAS FIR/LARCH <br />COMPLY WITH PS 20, AMERICAN SOFTWOOD LUMBER STANDARD AND <br />STANDARD GRADING RULES FOR WESTERN LUMBER. 19% MAXIMUM MOISTURE <br />CONTENT AT TIME OF PLACEMENT. <br />1.DIMENSION LUMBER: BLOCKING <br />(2" TO 4" THICK, 2" TO 4" & NONBEARING STUDS WIDE; STANDARD) <br />(10' MAXIMUM) <br />2.DIMENSION LUMBER: BEARING <br />(2" TO 4" THICK, 2" TO 4" STUDS JOISTS & RAFTERS WIDE; NO. 2) <br />3.DIMENSION LUMBER: JOISTS AND RAFTERS <br />(2" TO 4" THICK, 5" AND STUDS, BLOCKING, WIDER; NO. 2) <br />4.BEAMS AND STRINGERS: <br />(5" AND THICKER, WIDTH MORE THAN 2" GREATER THAN THICKNESS; NO. 1) <br />5.POSTS AND TIMBERS: <br />(4" AND 6", AND LARGER, WIDTH NOT MORE THAN 2" GREATER THAN <br />THICKNESS; NO.2) <br />6.HOLD DOWN POSTS: (NO. 2) <br />ENGINEERED LUMBER <br />1.LVL - LAMINATED VENEER LUMBER SHALL BE 2.0E MICROLLAM LVL. <br />2.PSL - PARALLEL STRAND LUMBER SHALL BE 2.0E PARALLAM PSL. <br />3.LSL - LAMINATED STRAND LUMBER SHALL BE 1.3E TIMBERSTRAND FOR <br />STUDS, RIM BOARDS AND BLOCKING, 1.55E TIMBERSTRAND FOR JOIST, BEAMS <br />AND HEADERS. <br />ENGINEERED LUMBER I-JOISTS <br />I-JOIST SHALL BE APA PERFORMANCE RATED MANUFACTURED IN <br />CONFORMANCE WITH PRI-400, PERFORMANCE STANDARD FOR APA EWS. <br />I-JOIST FLANGES TO HAVE MINIMUM WIDTH OF 1 1/2" 7 MINIMUM THICKNESS OF <br />1 5/16". WEBS TO BE PLYWOOD OR OSB WITH MINIMUM THICKNESS OF 3/8". FOR <br />ONE HOUR CONSTRUCTION, PRI-50 JOISTS ARE REQUIRED AT 24" OC. MAX., <br />SEE ESR-1405. PPROPER STORAGE, HANDLING AND INSTALLATION SHALL BE <br />FOR THESE PLANS AND MANUFACTURER'S PERCOMMENDATIONS. <br />WOOD STRUCTURAL PANELS (PANEL) <br />1.REFERENCES: PS1, PS2, APA STANDARD PRP-108, NATIONAL EVALUATION <br />SERVICE REPORT NER-108 <br />2.WALL PANELS..............OSB OR STRUCTURAL I, 15/32 INCH 32 <br />16 <br />3.ROOF PANELS..............OSB OR STRUCTURAL I, 15/32 INCH 32 <br />16 <br />4.FLOOR PANELS......................STURD-I-FLOOR, SANDED 19/32 INCH 20 OC, T&G <br />(EXTERIOR EXPOSURE AT BALCONIES AND DECKS) <br />5.BLOCKING: <br />A) WALLS: ALL UNSUPPORTED PANEL JOINTS SHALL BE BLOCKED SOLID <br />WITH 3x BLOCKING <br />B) FLOORS & ROOFS: WHERE NOTED ON THE DRAWINGS, ALL SUPPORT <br />PANEL JOINTS SHALL BE BLOCKED SOLID WITH 3x4 FLAT BLOCKING. <br />6.NAILING: COMMON WIRE NAILS. PANEL NAILS SHALL BE DRIVEN SO THAT <br />THE HEADS ARE FLUSH WITH THE SURFACE OF THE PANEL. FIELD NAILING (FN) <br />SHALL BE 12 INCHES ON CENTER AND THE MINIMUM PANEL EDGE DISTANCES <br />SHALL BE MAINTAINED. <br />7.MACHINE NAILING: SUBJECT TO A SATISFACTORY JOB SITE <br />DEMONSTRATION FOR THIS PROJECT AND REVIEW BY THE ENGINEER. THE USE <br />OF MACHINE NAILING IS SUBJECT TO CONTINUED SATISFACTORY <br />PERFORMANCE. PANEL NAILS SHALL BE DRIVEN SO THAT THE HEADS ARE <br />FLUSH WITH THE SURFACE OF THE PANEL AND THE MINIMUM PANEL EDGE <br />DISTANCES ARE MAINTAINED. <br />8.GLUED FLOORS: FIELD GLUE TO ALL SUPPORTS AND T&G EDGES PER APA, <br />AFG-01. FRAMING SHALL BE FREE OF SURFACE MOISTURE & DEBRIS PRIOR TO <br />GLUING. <br />9.WOOD STRUCTURAL PANELS (PANELS): WHERE ADJACENT WALLS ARE <br />PANELED, PANELS SHALL BE INSTALLED OVER AND UNDER OPENINGS. <br />SN1.0 GENERAL NOTE <br />S1.0 FOUNDATION PLAN <br />S2.0 ROOF FRAMING PLAN <br />SD1.0 DETAIL <br />DBL. <br />DET. <br />DIA. <br />DN. <br />DIM. <br />DWG. <br />DWLS. <br />(E) <br />EA. <br />E.E. <br />E.F. <br />EL. <br />E.N. <br />EQ. <br />E.S. <br />E.W. <br />CTR. <br />CTSK. <br />CONT. <br />CONC. <br />BTWN. <br />BOT. <br />BM. <br />BLDG. <br />ARCH. <br />A.B. <br />& <br />ABBREVIATION: <br />EACH FACE <br />ELEVATION <br />EDGE NAILING <br />EACH SIDE <br />EACH WAY <br />EQUAL <br />DIMENSION <br />EACH END <br />DRAWING <br />DOWELS <br />EXISTING <br />EACH <br />DOUBLE <br />DETAIL <br />DIAMETER <br />DOWN <br />ARCHITECTURAL <br />CONTINUOUS <br />COUNTERSUNK <br />CONCRETE <br />CENTER <br />BUILDING <br />BEAM <br />BOTTOM <br />BETWEEN <br />ANCHOR BOLT <br />AND <br />NORTHN. <br />N/A NOT APPLICABLE <br />EXP. <br />EXT. <br />F.F. <br />F.G. <br />FIN. <br />FL. <br />F.O.C. <br />FT. <br />FTG. <br />GLB <br />H.D. <br />HGR <br />HGT. <br />HK. <br />HORIZ. <br />H.S.B. <br />JST <br />JT. <br />L.S. <br />MAX. <br />M.B. <br />MECH. <br />MFR. <br />MIN. <br />MISC. <br />FINISH <br />MISCELLANEOUS <br />MANUFACTURER <br />MECHANICAL <br />MACHINE BOLT <br />LAG SCREW <br />HIGH STRENGTH BOLT <br />MINIMUM <br />MAXIMUM <br />JOINT <br />JOIST <br />HORIZONTAL <br />GLU-LAM BEAM <br />FOOT OR FEET <br />FACE OF CONCRETE <br />HOOK <br />HEIGHT <br />HANGER <br />HOLDOWN <br />FOOTING <br />FLOOR <br />FINISH GRADE <br />EXPANSION <br />FINISH FLOOR <br />EXTERIOR <br />N.I.C. <br />No. or # <br />O.C. <br />N.T.S. <br />OPP. <br />OWJ <br />OWG <br />PL. <br />PLYWD <br />RAD. <br />REF. <br />REINF. <br />REQD. <br />S.A.D. <br />SCHED. <br />SECT. <br />SIM. <br />SPEC. <br />SQ. <br />STAGG. <br />STD. <br />STL. <br />SYM. <br />SPA. <br />T.&B. <br />THK. <br />T.O.F. <br />SQUARE <br />TOP OF FOOTING <br />TOP & BOTTOM <br />SYMMETRICAL <br />STANDARD <br />STAGGERED <br />THICK <br />SPACING <br />STEEL <br />PLYWOOD <br />SPECIFICATION <br />SCHEDULED <br />SEE ARCH DRAWING <br />REINFORCED <br />REFERENCE <br />SIMILAR <br />SECTION <br />REQUIRED <br />RADIUS <br />OPEN WEB STEEL GIRDER <br />OPEN WEB JOIST <br />ON CENTER <br />NOT TO SCALE <br />NOT IN CONTRACT <br />PLATE <br />OPPOSITE <br />NUMBER <br />TYP. <br />U.O.N. <br />VERT. <br />W/ <br />W/O <br />WP. <br />W.W.F.WELDED WIRE FABRIC <br />WATERPROOF <br />UNLESS OTHERWISE NOTED <br />WITHOUT <br />WITH <br />VERTICAL <br />TYPICAL <br />SOUTHBAY <br />STRUCTURE <br />66 <br />6 <br />3 <br /> <br />O <br />W <br />E <br />N <br />S <br /> <br />D <br />R <br />, <br />PL <br />E <br />A <br />S <br />A <br />N <br />T <br />O <br />N <br />, <br />C <br />A <br /> <br />9 <br />4 <br />5 <br />8 <br />8 <br />Ac <br />a <br />d <br />e <br />m <br />i <br />c <br /> <br />C <br />e <br />n <br />t <br />e <br />r <br /> <br />o <br />f <br /> <br />V <br />o <br />l <br />i <br />t <br />a <br />t <br />i <br />o <br />n <br />, <br /> <br />C <br />o <br />r <br />p <br />. <br />Da <br />y <br />c <br />a <br />r <br />e