N
<br />N
<br />1. CONTRACTORS SHALL VERIFY ALL DIMENSIONS WITH
<br />CONDITIONS AT THE JOB SITE BEFORE PROCEEDING WITH
<br />ANY WORK. CONTRACTORS SHALL NOTIFY PROJECT
<br />DESIGNER IF EXISTING CONDITIONS DIFFER FROM THOSE
<br />ON DRAWINGS.
<br />2. ALL DIMENSIONS SHALL BE AS INDICATED ON
<br />DRAWINGS OR AS CLARIFIED BY PROJECT DESIGNER.
<br />UNDER NO CIRCUMSTANCES SHALL DIMENSIONS BE
<br />DETERMINED BY SCALING THE DRAWINGS.
<br />3. ANY ERRORS, OMISSIONS, OR CONFLICTS FOUND IN
<br />THE VARIOUS PARTS OF THE CONSTRUCTION
<br />DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF
<br />THE PROJECT DESIGNER PRIOR TO COMMENCEMENT OF
<br />WORK.
<br />4. ALL WORK SHALL COMPLY WITH ALL APPLICABLE
<br />CODES, ORDINANCES, AND THE HIGHEST STANDARDS OF
<br />THE TRADE.
<br />5. ALL WORK SHALL BE DONE IN A SAFE, ORDERLY
<br />MANNER WITHOUT DAMAGE TO OTHER PARTS OF THE
<br />PREMISES OR ADJACENT PROPERTIES.
<br />6. NO MATERIALS CONTAINING ASBESTOS MAY BE USED.
<br />SHEET INDEX
<br />SCOPE OF WORK CONTACT LIST
<br />CITY OF PLEASANTON MUNICIPAL CODE
<br />2022 CBC, CALIFORNIA BUILDING CODE
<br />2022 CRC, CALIFORNIA RESIDENTIAL CODE
<br />2022 CMC, CALIFORNIA MECHANICAL CODE
<br />2022 CEC, CALIFORNIA ELECTRICAL CODE
<br />2022 CPC, CALIFORNIA PLUMBING CODE
<br />2022 CFC, CALIFORNIA FIRE CODE
<br />2022 CCR, CALIFORNIA CODE OF REGULATIONS, TITLE 24
<br />2022 CALIFORNIA GREEN BUILDING STANDARD CODE
<br />2022 CALIFORNIA ENERGY CODE
<br />PARCEL MAP
<br />VICINITY MAPCODE COMPLIANCE
<br />GENERAL NOTES GREEN CODEABBREVIATIONS
<br />1. INTERIOR REMODEL OF EDUCATION/BUSINESS UNIT TO
<br />ADD DAYCARE USE FOR 18 MONTHS TO FIVE YEARS OLD
<br />CHILDREN.
<br />2. CONVERT EXISTING OFFICES TO NEW DAYCARE ROOMS.
<br />3. PROVIDE TOTAL 6 DAYCARE ROOM TO SUPPORT NINETY
<br />THREE STUDENTS (FIVE YOUNGER THAN 36 MONTHS
<br />INFANTS AND TODDLERS AND EIGHTY-EIGHT 36 MONTHS OR
<br />OLDER CHILDREN).
<br />4. CHANGE INDOOR PLAY AREA TO INCLUDE READING AREA
<br />AND BOOK STACK AREA.
<br />5. CONVERT 9 PARKING SLOTS TO 1364 SF OUTDOOR PLAY
<br />GROUND, MODIFY LANDSCAPE AND SIDEWALK AS NEEDED
<br />TO ACHIEVE THE DESIGN.
<br />ACADEMIC CENTER OF
<br />VOLITATION, CORP.
<br />PRESCHOOL
<br />6663 OWENS DR,
<br />PLEASANTON, CA 94588
<br />SITE
<br />SITE
<br />PROPERTY INFORMATION
<br />ZONING:PUD-1/C-O
<br />APN:941-1301-064-00
<br />OCCUPANCY:B AND E
<br />OCCUPANCY LOAD:222, TOTAL 93 STUDENTS
<br />AGE OF STUDENTS: 18 MONTHS TO 5 YEARS
<br />HOURS OF OPERATION: 8 AM - 6 PM, MONDAY TO FRIDAY
<br />AVERAGE TEACHER TO STUDENTS: 8:1
<br />TYPE OF CONSTRUCTION:TYPE V-B
<br />FIRE SPRINKLERS:YES (EXISTING)
<br />EXISTING PARKING:173 (OFF STREET, V.I.F)
<br />PROPOSED PARKING:164 (OFF STREET, V.I.F)
<br />LOT AREA:156,380 SF
<br />EXISTING PROPOSED TOTAL
<br />BUILDING FLOOR AREA:11,135 SF NO CHANGE 11,135 SF
<br />BUILDING FOOTPRINT:11,135 SF NO CHANGE 11,135 SF
<br />@ AT
<br />ACOUS.ACCOUSTICAL
<br />A.D.AREA DRAIN
<br />ADJ.ADJUSTABLE OR
<br />ADJACENT
<br />A.G.ABOVE GRADE
<br />A.F.F.ABOVE FINISHED
<br />FLOOR
<br />AL.ALUMINUM
<br />ARCH.ARCHITECTURAL
<br />ASPH.ASPHALT
<br />BD.BOARD
<br />BLDG.BUILDING
<br />BM.BEAM
<br />CH.CEILING HEIGHT
<br />CAB.CABINET
<br />CEM.CEMENT
<br />CER.CERAMIC
<br />CLR.CLEAR
<br />COL.COLUMN
<br />CONSTR.CONSTRUCTION
<br />CONT.CONTINUOUS
<br />CONC.CONCRETE
<br />D.DEEP
<br />DIA.DIAMETER
<br />DS.DOWNSPOUT
<br />DWG.DRAWING
<br />ELEV.ELEVATION
<br />(E)EXISTING
<br />E.EAST
<br />EA.EACH
<br />ELEC.ELECTRICAL
<br />EQ.EQUAL
<br />EXT.EXTERIOR
<br />EXP.EXPANSION
<br />F.E.C.FIRE EXTINGUISHER
<br />CABINET
<br />FIN.FINISH
<br />FLR.FLOOR
<br />FLUOR.FLUORESCENT
<br />F.O.F.FACE OF FINISH
<br />F.O.S.FACE OF STUD
<br />FT.FOOT OR FEET
<br />GALV.GALVANIZED
<br />GA.GAUGE
<br />GL.GLASS
<br />GYP.GYPSUM
<br />HT.HEIGHT
<br />HEX.HEXAGON
<br />H.HIGH
<br />H.C.HOLLOW CORE
<br />H.M.HOLLOW METAL
<br />HR.HOUR
<br />INSUL.INSULATION
<br />INT.INTERIOR
<br />L.LONG
<br />LT.LIGHT
<br />MIN.MINIMUM
<br />MTD.MOUNTED
<br />(N)NEW
<br />N.NORTH
<br />N.I.C.NOT IN CONTRACT
<br />NO.OR # NUMBER OR POUND
<br />N.T.S.NOT TO SCALE
<br />O.A.OVERALL
<br />O.C.ON CENTER
<br />O.H.OPPOSITE HAND
<br />P.D.P.POWDER DRIVEN PIN
<br />PL.PLATE
<br />P.LAM.PLASTIC LAMINATE
<br />PLYWD.PLYWOOD
<br />(R)REMOVE(D)
<br />R.RADIUS
<br />REQ.REQUIRE(D)
<br />RM.ROOM
<br />R.O.ROUGH OPENING
<br />S.C.SOLID CORE
<br />SCHED.SCHEDULED
<br />SIM.SIMILAR
<br />SHT.SHEET
<br />SPEC.SPECIFICATION
<br />STD.STANDARD
<br />STOR.STORAGE
<br />SUSP.SUSPENDED
<br />S/S STAINLESS STEEL
<br />SQ.SQUARE
<br />TEL.TELEPHONE
<br />T.&G.TONGUE & GROOVE
<br />THK.THICK
<br />TYP.TYPICAL
<br />U.O.N.UNLESS OTHERWISE NOTED
<br />VERT.VERTICAL
<br />V.I.F.VERIFY IN FIELD
<br />V.C.T.VINYL COMPOSITION TILE
<br />W.C.WATER CLOSET
<br />WD.WOOD
<br />W/WITH
<br />W/O WITHOUT
<br />WP.WATERPROOF
<br />W.R.WATER RESISTANT
<br />WT.WEIGHT
<br />PROJECT ADDRESS:
<br />6663 OWENS DR.
<br />PLEASANTON, CA 94588
<br />OWNER:
<br />RAY ZHAO
<br />CELL: (925) 353-888
<br />EMAIL: [email protected]
<br />DESIGNER:
<br />ORANGE ENGINEERING LLC
<br />4005 CLIPPER CT
<br />FREMONT, CA 94538
<br />(408)888-7836
<br />[email protected]
<br />[email protected]
<br />MEP ENGINEER:
<br />CDI, INC.
<br />16520 BAKE PARKWAY, SUITE 100
<br />IRVINE, CA 92618
<br />(949)336-6636
<br />A 0.0 COVER SHEET
<br />A 1.0 EXISTING SITE PLAN
<br />A 1.1 PROPOSED SITE PLAN
<br />A 1.2 PROPOSED PLAYGROUND PLAN
<br />A 2.0 EXISTING FLOOR PLAN
<br />A 2.1 PROPOSED FLOOR PLAN
<br />A 3.0 PATH OF EGRESS
<br />A 4.0 EXISTING CEILING PLAN
<br />A 4.1 PROPOSED CEILING PLAN
<br />A 5.0 PROPOSED FENCE ELEVATIONS
<br />A 7.0 ADA DETAILS
<br />C1.0 CLEAN BAY BLUE PRINT
<br />STRUCTURAL
<br />SN1.0 GENERAL NOTE
<br />S1.0 FOUNDATION PLAN
<br />S2.0 ROOF FRAMING PLAN
<br />SD1.0 DETAIL
<br />MECHANICAL
<br />M000 MECHANICAL NOTES
<br />M001 MECHANICAL SCHEDULES & DETAILS
<br />M100 MECHANICAL PLAN
<br />M1.1 MECHANICAL PLAN - ROOF PLAN
<br />TM00 MECHANICAL TITLE 24-1
<br />ELECTRICAL
<br />E000 ELECTRICAL SPECIFICATION
<br />E001 SINGLE LINE DIAGRAM/SCHEDULES
<br />E100 LIGHTING PLAN
<br />E200 POWER PLAN
<br />G1. ANNULAR SPACES AROUND PIPES, ELECTRIC
<br />CABLES, CONDUITS OR OTHER OPENINGS IN SOLE/
<br />BOTTOM PLATES AT EXTERIOR WALLS SHALL BE
<br />CLOSED WITH CEMENT MORTAR, CONCRETE
<br />MASONRY OR A SIMILAR METHOD ACCEPTABLE TO THE
<br />ENFORCING AGENCY TO PREVENT PASSAGE OF
<br />RODENTS PER CGBSC 4.406.1.
<br />G2. MIN. 65% OF THE CONSTRUCTION WASTE
<br />GENERATED SHALL BE RECYCLED AND/OR SALVAGED
<br />PER CGBSC 4.408.1.
<br />G3. AN OPERATION AND MAINTENANCE MANUAL SHALL
<br />BE PROVIDED TO THE BUILDING OCCUPANT OR
<br />OWNER PER CGBSC 4.410.1.
<br />G4. AT THE TIME OF ROUGH INSTALLATION, DURING
<br />STORAGE ON THE CONSTRUCTION SITE AND UNTIL
<br />FINAL STARTUP OF THE HEATING, COOLING AND
<br />VENTILATING EQUIPMENT, ALL DUCT AND OTHER
<br />RELATED AIR INTAKE AND DISTRIBUTION COMPONENT
<br />OPENINGS SHALL BE COVERED. TAPE, PLASTIC, SHEET
<br />METALS, OR OTHER METHODS ACCEPTABLE TO THE
<br />ENFORCING AGENCY TO REDUCE THE AMOUNT OF
<br />WATER, DUST AND DEBRIS ENTERING THE SYSTEM
<br />MAY BE USED PER CGBSC 4.504.1.
<br />G5. FINISH MATERIALS SHALL COMPLY WITH SECTION
<br />4.504.2.1 THROUGH 4.504.5.1.
<br />G6. ADHESIVES, SEALANT AND CAULKS SHALL BE
<br />COMPLIANT WITH VOC OR OTHER TOXIC COMPOUND
<br />LIMIT PER CGBSC 4.504.2.1.
<br />G7. PAINT AND COATING SHALL BE COMPLIANT WITH
<br />VOC LIMIT PER CGBSC 4.504.2.2.
<br />G8. AEROSOL PAINTS AND COATINGS SHALL BE
<br />COMPLIANT WITH PRODUCT WEIGHTED MIR LIMITS
<br />FOR ROC OR OTHER TOXIC COMPOUND PER CGBSC
<br />4.504.2.3.
<br />G9. DOCUMENTATION SHALL BE PROVIDED TO THE
<br />CITY BUILDING INSPECTOR UPON REQUEST,
<br />VERIFYING THAT COMPLIANT VOC LIMIT MATERIALS
<br />HAVE BEEN USED PER CGBSC 4.504.2.4.
<br />G10. ALL CARPET AND CARPET SYSTEMS SHALL BE
<br />COMPLIANT WITH VOC LIMIT PER CGBSC 4.504.3.
<br />G11. 80% OF FLOOR AREA RECEIVING RESILIENT
<br />FLOORING SHALL COMPLY WITH VOC EMISSION LIMITS
<br />DEFINED IN THE COLLABORATIVE FOR HIGH
<br />PERFORMANCE PRODUCT (CHPS) LOW-EMITTING
<br />MATERIAL LIST OR BE CERTIFIED UNDER THE
<br />RESILIENT FLOOR COVERING INSTITUTE (RCFI)
<br />FLOOR SCORE PROGRAM PER CGBSC 4.504.3.4.
<br />G12. HARDWOOD PLYWOOD, PARTICLEBOARD AND
<br />MEDIUM DENSITY FIBERBOARD COMPOSITE WOOD
<br />PRODUCTS USED ON THE INTERIOR OR EXTERIOR OF
<br />THE BUILDING SHALL BE COMPLIANT WITH LOW
<br />FORMALDEHYDE EMISSIONS STANDARDS PER CGBSC
<br />4.504.5.
<br />G13. A CAPILLARY BREAK SHALL BE INSTALLED IF A
<br />SLAB ON GRADE FOUNDATION SYSTEM IS USED. THE
<br />USE OF A 4” THICK BASE OF ½” OR LARGER CLEAN
<br />AGGREGATE UNDER A 6-MIL VAPOR RETARDER WITH
<br />JOINT LAPPED NOT LESS THAN 6” WILL BE PROVIDED
<br />PER CGBSC 4.505.2 AND CRC R506.2.3.
<br />G14. BUILDING MATERIALS WITH VISIBLE SIGNS OF
<br />WATER DAMAGE SHALL NOT BE INSTALLED. WALL AND
<br />FLOOR FRAMING SHALL NOT BE ENCLOSED WHEN THE
<br />FRAMING MEMBERS EXCEED 19% MOISTURE
<br />CONTENT. MOISTURE CONTENT SHALL BE VERIFIED IN
<br />COMPLIANCE WITH THE CGBSC 4.505.3.
<br />G15. INSTALL ENERGY STAR BATHROOM FANS ON
<br />TIMER OR HUMIDISTAT AND BE DUCTED TO TERMINATE
<br />OUTSIDE THE BUILDING, SHALL BE PROVIDED IN
<br />EVERY NEW/REMODELED BATHROOM PER CGBSC
<br />4.506.1.
<br />G16. HEATING AND AIR-CONDITIONING SYSTEMS
<br />SHALL BE SIZED, DESIGNED AND HAVE THEIR
<br />EQUIPMENT SELECTED USING THE FOLLOWING
<br />METHODS (CGBSC 4.507.2):
<br />1.THE HEAT LOSS AND HEAT GAIN IS ESTABLISHED
<br />ACCORDING TO ANSI/ACCA 2 MANUAL J-2011 OR
<br />EQUAL;
<br />2.DUCT SYSTEMS ARE SIZED ACCORDING TO ANSI/
<br />ACCA 1 MANUAL D-2014 OR EQUAL.
<br />3.SELECT HEATING AND COOLING EQUIPMENT
<br />ACCORDING TO ANSI/ACCA3 MANUAL S-2014 OR
<br />EQUAL
<br />4.EXCEPTION: USE OF ALTERNATE DESIGN
<br />TEMPERATURES NECESSARY TO ENSURE THE
<br />SYSTEMS FUNCTION ARE ACCEPTABLE.
<br />G17. HVAC SYSTEM INSTALLERS SHALL BE TRAINED
<br />AND CERTIFIED IN THE PROPER INSTALLATION OF
<br />HVAC SYSTEMS AND EQUIPMENTS BY A RECOGNIZED
<br />TRAINING OR CERTIFICATION PROGRAM PER CGBSC
<br />702.1.
<br />G18. DOCUMENTATION OF COMPLIANCE SHALL
<br />INCLUDE, BUT IS NOT LIMITED TO, CONSTRUCTION
<br />DOCUMENTS, PLANS, SPECIFICATIONS, BUILDER OR
<br />INSTALLER CERTIFICATION, INSPECTION REPORTS, OR
<br />OTHER METHODS ACCEPTABLE TO THE LOCAL
<br />ENFORCING AGENCY. OTHER SPECIFIC
<br />DOCUMENTATION OR SPECIAL INSPECTIONS
<br />NECESSARY TO VERIFY COMPLIANCE ARE SPECIFIED
<br />IN APPROPRIATE SECTIONS OF CALGREEN PER
<br />CGBSC 4.703.
<br />A 0.0
<br />ORANGE
<br />ENGINEERING
<br />4005 CLIPPER CT
<br />FREMONT, CA 94538
<br />TEL (408) 888-7836
<br />OE2303
<br />11/22/23
<br />9
<br />8
<br />7
<br />6
<br />5
<br />4
<br />3
<br />2
<br />DATE:
<br />JOB NO.
<br />ISSUE & REVISION
<br />SHEET NO.
<br />DRAWN BY:
<br />1
<br />CITY SUBMITTALMM/DD/YY
<br />6663 OWENS DR,
<br />PLEASANTON, CA 94588
<br />ACADEMIC CENTER OF VOLITATION,
<br />CORP. - PRESCHOOL
<br />SHEET NAME.
<br />SY-CHENG TSAI C-24234
<br />1/31/25
<br />DATE
<br />RENEWAL
<br />SY-CHENG TSAI
<br />T
<br />AR
<br />C
<br />H
<br />E
<br />I
<br />T
<br />C
<br />LI
<br />DESECN
<br />N IA
<br />AC FIL O R
<br />S
<br />OF
<br />T
<br />T
<br />A
<br />E
<br />C-24234
<br />COVER SHEET
<br />ARCHITECTURAL
<br />11
<br />11
<br />DEFERRED SUBMITTAL
<br />FIRE ALARM SHALL BE DEFERRED SUBMITTAL
<br />FIRE SPRINKLER SHALL BE DEFERRED SUBMITTAL
<br />11
<br />09/03/2024 PLANNING REV1
<br />11
|