Laserfiche WebLink
Page 2 of 7 <br />forth the rights and responsibilities between the City and the property owner/developer. DAs <br />are primarily utilized on large, master planned developments constructed in a phased manner <br />over a relatively long period of time, and often require significant investments in public <br />infrastructure on the part of the private developer. DAs encourage private investment, <br />including the provision of public facilities that would not normally be required under a typical <br />development plan review. <br /> <br />In November 1992, the City Council approved the original DA (Attachment 2) for the <br />Stoneridge Shopping Center, which granted rights to expand the shopping center by <br />approximately 178,000 square feet in exchange for developer contributions to various traffic <br />improvements and approved a related Sewer Agreement that reserved and allocated sewer <br />capacity for the uses within the shopping center. <br /> <br />On January 6, 1998, the City Council approved the First Amendment to the DA, further <br />increasing the Stoneridge Shopping Center by an additional 202,000 square feet, thereby <br />totaling 380,000 square feet of expansion area, and modified the traffic improvements. An <br />amendment to the Sewer Agreement was also approved at that time which reserved 10,000 <br />gallons of sewer capacity for the shopping center. <br /> <br />In summary, the original DA, as amended by the First Amendment, and related Sewer <br />Agreement, granted the following entitlements and restrictions to the owners of the shopping <br />center and their successors: <br />• Permitted the expansion of the shopping center floor area by a total of 380,000 square <br />feet (the additional to-be-developed area has been reduced to 362,790 square feet of <br />floor area due to the past construction of the P.F. Chang’s and Cheesecake Factory <br />restaurants). Also, Design Review approval was granted in 2019 for the Stoneridge <br />Mall Commercial Replacement and Expansion Project by Planning Commission <br />Resolution PC-2019-10 for net new construction of 79,269 square feet, but none of that <br />square footage has been constructed. Accordingly, the total approved expansion <br />remains at 362,790 square feet) <br />• Reserved 10,000 gallons per day of sewer capacity for the entire shopping center (this <br />capacity has been used completely by the present shopping center retail businesses <br />and restaurants) <br />• Referenced the permitted and conditional uses of the Regional Commercial – Mall <br />Complex (CR(m)) District of the Pleasanton Municipal Code (PMC) for the shopping <br />center with the applicable City approvals <br />• Established parking ratios between 3.5 and 4.5 parking spaces per 1,000 square feet of <br />floor area for different categories of shopping center uses (these vested parking ratios <br />exceed the City’s current typical retail parking standard of 3.33 parking spaces per <br />1,000 square feet) <br />• Required the shopping center to participate in mitigation measures identified by the City <br />to offset the anticipated traffic impacts of the I-680/West Las Positas Road freeway <br />interchange (which was subsequently determined by the City not to be built) <br />• Defined the maximum height for all new shopping center buildings as that of the highest <br />building existing at the time of the First Amendment, which is 68 feet <br />• Permitted parking decks up to a maximum height of three levels above grade <br />• Identified traffic improvements to nearby intersections that could be required by the <br />Page 29 of 371