My WebLink
|
Help
|
About
|
Sign Out
PC-97-22
City of Pleasanton
>
BOARDS AND COMMISSIONS
>
PLANNING
>
RESOLUTIONS
>
1990-1999
>
1997
>
PC-97-22
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/15/2006 9:33:06 AM
Creation date
11/17/2004 4:33:03 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
RESOLUTIONS
DOCUMENT DATE
2/26/1997
DOCUMENT NO
PC-97-22
DOCUMENT NAME
Z-96-275/UP-97-05
NOTES
VALLEY COMMUNITY CHURCH
NOTES 3
APPROVED /CUP
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br />Resolution No. PC-97-22 <br />Page 7 <br /> <br />23. All parking spaces shall be striped. Wheel stops shall be provided unless the spaces are <br />fronted by concrete curbs, in which case sufficient areas shall be provided beyond the <br />ends of all parking spaces to accommodate the overhang of automobiles. <br /> <br />24. All utilities required to serve any existing or proposed development on-site shall be <br />installed underground, unless otherwise determined by the City Engineer. <br /> <br />25. The applicant shall enter into an agreement with the City, approved by the City Attorney, <br />which guarantees that all landscaping and open space areas included in this project will <br />be maintained at all times in a manner consistent with the approved landscape plan for <br />this development. Said agreement shall run with the land for the duration of the existence <br />of the structures located on the subject property. <br /> <br />26. The location of any pad mounted transformers shall be subject to approval by the <br />Planning Director prior to issuance of permits by the Building Department. Such <br />transformers shall be screened by landscaping or contained within an enclosure matching <br />the building and with corrugated metal gates. All transformers shall be shown on the <br />plans submitted for issuance of building permits. The applicant shall attempt to locate <br />transformers at the rear of the site. <br /> <br />27. A final landscape plan and irrigation plan shall be submitted to and approved by Planning <br />Director as part of the building permit plan set prior to issuance of an on-site permit. <br />Said landscape plan shall be consistent with the approved landscape plan plus any <br />conditions of approval, and shall be detailed in terms of species, location, size, quantities, <br />and spacing. <br /> <br />28. All trees used in landscaping be a minimum of 15 gallons in size and all shrubs a <br />minimum of 5 gallons, unless otherwise shown on the approved landscape plan. <br /> <br />29. Six inch vertical concrete curbs shall be installed between all paved and landscaped areas. <br /> <br />30. The applicant shall provide root control barriers and four inch perforated pipes for <br />parking lot trees, street trees, and trees in planting areas less than ten feet in width, as <br />determined necessary by the Planning Director at the time of review of the final <br />landscape plans. <br /> <br />31. Prior to occupancy, the landscape architect shall certify in writing to the Planning <br />Director that the landscaping has been installed in accordance with the approved <br />landscape and irrigation plans with respect to size, number, and species of plants and <br />overall design concept. <br /> <br />32. Approved building colors shall be stated on the plans submitted for issuance of building <br />permits. <br />
The URL can be used to link to this page
Your browser does not support the video tag.