Laserfiche WebLink
Objective Design Standards for Housing Sites <br />City of Pleasanton - 47 - Adopted January 26, 2023 <br /> <br /> <br />Single Family Tract Development <br />Single Family Homes and Primary Structures of Multiple Single Family Development on the same <br />parcel shall comply with the following massing standards: <br />B1.3 Elevations fronting Public Streets, Internal Streets, Paseos, Open Spaces, or the City of <br />Pleasanton Trail System shall limit any continuous plane to 40% of the total façade length <br />through the use of recesses or projections not less than three feet in depth from the adjacent wall. <br />B1.4 Garages shall comply with the following standards: <br />a. Garages shall not be oriented to face Paseos or the city public Trail System <br />b. Garages facing Public Streets and Internal Streets shall be limited to <br />i. 30% of the total width of the home façade, for lot frontages over in excess <br />of 80 feet wide <br />ii. 40% of the total width of the front home façade, for lot frontages over <br />between 60 to 80 feet wide, <br /> <br />0. 50% of the total width of the front home façade, for lot frontages less than <br />60 over 45 feet wide . <br />iv.iii. or 22 feet garage interior clear width, whichever is greater, <br />v.iv. For parcels under 10,000 square feet s.f. three- car garages shall use <br />tandem parking for third space within the garage. <br />B1.5 a. Residential floor area for each floor above the ground floor shall comply with the following <br />standardsnot exceed 75% of the ground floor area inclusive of any attached garages.: <br /> <br /> <br />a. Floor area of any floor above the ground floor shall be no greater than: <br />i. 40% of allowed building coverage for lots greater than 8,000 square.feet. <br />ii. 50% of allowed building coverage for lots of greater than 6,500 square feet <br />and up to 8,000 square feet. <br />iii. 60% of allowed building coverage for lots over 4,500 square feet and up to <br />6,500 square feet. <br />iv.80% of allowed building coverage for lots up to 4,500 square feet. <br /> <br /> <br />b. Floor area located under sloping roofs shall be counted in accordance with the ANSI Z765 <br />standard: <br /> .i. Residential floor area above the ground floor must have a minimum clearance of 5 feet <br />above the finished floor <br /> .ii. 50% of the floor area above the ground floor must have ceilings at least 7 feet above the <br />finished floor. <br />DocuSign Envelope ID: C076F9B8-9653-46AC-8C4E-92058DC31D9E