Laserfiche WebLink
Ordinance No.2245 <br /> Page 32 of 37 <br /> 103. FIRE LANE MARKING: On-site access ways, turn arounds, and internal drives shall be <br /> designated as fire lanes and identified as such by red curb striping and posted with signs <br /> at locations approve by the Fire Department. Signs shall be according to State standards <br /> and read "No Parking — Fire Lane" and must be shown on the plans. The red curb <br /> striping, sign location(s), and sign language shall be included in the building permit <br /> submittal for review and approval by the Livermore-Pleasanton Fire Department prior to <br /> building permit issuance. <br /> a. The following schedule for NO PARKING signs shall apply: <br /> Width Requirements <br /> Approximately 36 feet or greater No requirements <br /> Between approximately 28 and 36 feet Post one side <br /> Between approximately 20 and 28 feet Post both sides <br /> Less than approximately 20 feet Not permitted <br /> Cul-de-Sac Not permitted <br /> 104. EMERGENCY VEHICLE ACCESS ROADS: Access roads shall have approximately 13 <br /> feet and six inches unobstructed vertical clearance, approximately 20 feet of <br /> unobstructed width (approximately 26 feet where occupied building floors exceed <br /> approximately 30 feet height), and inside turning radius of approximately 31 feet and <br /> outside turning radius of approximately 51 feet. Unobstructed shall mean a clear travel <br /> way, excluding parking width, and designed for an emergency vehicle weight of <br /> approximately 70,000 pounds under all weather conditions. Unobstructed width shall not <br /> include the width of rolled curbs, sidewalks, or non-drivable surfaces. All exterior <br /> portions of buildings must be within approximately 200 feet of an access road. Yard and <br /> parking area may be able to be located farther than approximately 200 feet from access <br /> roads, depending on the specific use. <br /> 105. FIRE VEHICLE TURNAROUNDS: Where Fire Department vehicle access through or <br /> around a site involves changes in direction or curves, inside radius of 45 feet and <br /> outside radius of 55 feet shall be provided to facilitate fire truck turning radius for entry <br /> and exit from the site. Dead-end access ways and internal drives shall not exceed 300 <br /> feet in length and shall terminate in cul-de-sacs no less than 96 feet in diameter or <br /> hammer-head (tee). Standards and options are available through the Livermore- <br /> Pleasanton Fire Department, Fire Prevention Bureau. <br /> 106. PREMISES IDENTIFICATION: Address numbers shall be installed on the front or <br /> primary entrance for all buildings. Minimum building address character size shall be 12- <br /> inch high by 1-inch stroke. In all cases address numerals shall be of contrasting <br /> background and clearly visible in accordance with the Livermore-Pleasanton Fire <br /> Department Premises Identification Standards. This may warrant field verification and <br /> adjustments based upon topography, landscaping or other obstructions. <br />