20.24.430 <br /> 801 (Pleasanton Supp. No. 29, 1-23) <br />20.24.430 CFC Section 6004.1.15 added—Inert <br />gas purge system. <br /> Section 6004.1.15 is added to read: <br /> <br />6004.1.15 Inert gas purge system. Gas systems <br />shall be provided with dedicated inert gas purge <br />systems. A dedicated inert gas purge system may <br />be used to purge more than one gas, provided the <br />gases are compatible. Purge gas systems inside <br />buildings shall be located in an approved gas cabi- <br />net unless the system operates by vacuum demand. <br /> <br />Exception: Refrigeration systems. <br />(Ord. 2241 § 2, 2022; Ord. 2197 § 2, 2019) <br /> <br />20.24.440 CFC Section 6004.1.16 added—Seismic <br />shutoff valve. <br /> Section 6004.1.16 is added to read: <br /> <br />6004.1.16 Seismic shutoff valve. An automatic <br />seismic shut-off valve, which is of a fail-safe to <br />close design, shall be provided to shutoff the sup- <br />ply of highly toxic, toxic and moderately toxic <br />gases with an LC50 less than 3,000 parts per mil- <br />lion upon a seismic event within 5 seconds of a <br />horizontal sinusoidal oscillation having a peak ac- <br />celeration of 0.3G (1.47m/sec2) and a period of 0.4 <br />seconds. <br />(Ord. 2241 § 2, 2022; Ord. 2197 § 2, 2019) <br /> <br />20.24.450 CFC Section 6004.1.17 added— <br />Fittings and connections. <br /> Section 6004.1.17 is added to read: <br /> <br />6004.1.17 Fittings and connections. Fittings and <br />connections shall be located in a gas cabinet, ex- <br />hausted enclosure, gas room or exhausted valve <br />manifold box. <br /> <br />Exception: Welded connections. <br />(Ord. 2241 § 2, 2022; Ord. 2197 § 2, 2019) <br /> <br />20.24.460 CFC Section 6004.2 amended—Indoor <br />storage and use. <br /> Section 6004.2 is hereby amended to read: <br /> <br />6004.2 Indoor storage and use amended. The <br />indoor storage or use of highly toxic, toxic and <br />moderately toxic compressed gases shall be in ac- <br />cordance with Sections 6004.2.1 through <br />6004.2.2.10.4. <br />(Ord. 2241 § 2, 2022; Ord. 2197 § 2, 2019) <br /> <br />20.24.470 CFC Section 6004.2.1 amended— <br />Applicability. <br /> Section 6004.2.1 is hereby amended to read: <br /> <br />6004.2.1 Applicability. The applicability of regu- <br />lations governing the indoor storage and use of <br />highly toxic, toxic and moderately toxic com- <br />pressed gases shall be in accordance with Sections <br />6004.2.1.1 through 6004.2.1.5. <br />(Ord. 2241 § 2, 2022; Ord. 2197 § 2, 2019) <br /> <br />20.24.480 CFC Section 6004.2.1.1 amended— <br />Quantities not exceeding the maximum <br />allowable quantity per control area. <br /> Section 6004.2.1.1 is hereby amended to read: <br /> <br />6004.2.1.1 Quantities not exceeding the maxi- <br />mum allowable quantity per control area. The <br />indoor storage or use of highly toxic and toxic <br />compressed gases in amounts not exceeding the <br />maximum allowable quantity per control area set <br />forth in Table 5003.1.1(2) shall be in accordance <br />with Sections 5001, 5003, 6001, 6004.1, <br />6004.2.1.4 and 6004.2.1.5. <br />(Ord. 2241 § 2, 2022; Ord. 2197 § 2, 2019) <br /> <br />20.24.490 CFC Section 6004.2.1.4 added— <br />Quantities not exceeding minimum <br />threshold quantity per control area. <br /> Section 6004.2.1.4 is added to read: <br /> <br />6004.2.1.4 Quantities not exceeding minimum <br />threshold quantity per control area. The indoor <br />storage or use of highly toxic, toxic and moder- <br />ately toxic gases in amounts not exceeding the <br />minimum threshold quantity per control area set <br />forth in Table 6004.1 shall be in accordance with <br />Sections 6001, and 6004.1 and Chapter 50. <br />(Ord. 2241 § 2, 2022; Ord. 2197 § 2, 2019) <br /> <br />20.24.500 CFC Section 6004.2.1.5 amended— <br />Quantities exceeding minimum <br />threshold quantity per control area. <br /> Section 6004.2.1 is added to read: <br /> <br />6004.2.1.5 Quantities exceeding the minimum <br />threshold quantity per control area. The indoor <br />storage or use of highly toxic, toxic and moder- <br />ately gases in amounts exceeding the minimum <br />threshold quantity per control area set forth in Ta-