Laserfiche WebLink
PUD-136, Mall Residential Project Planning Commission <br />28 of 34 <br />Parking <br />Pursuant to State Density Bonus Law, because the project is located near a major transit stop <br />and would provide more than 20 percent low-income units, the City may not impose a parking <br />ratio, inclusive of disability and guest parking, of more than half a parking space per unit. (See <br />Cal. Gov’t Code § 65915(p)). Accordingly, 180 parking spaces are required (360 units x 0.5 <br />spaces per unit = 180 parking spaces). Notwithstanding the ability to reduce required parking, <br />the applicant has not asked to exercise these provisions. Instead, the project will provide more <br />than double the required amount of parking spaces for a total of 473 total parking spaces, <br />which will allow approximately 1.3 parking spaces per unit and a surplus of 293 parking <br />spaces. Designated guest spaces would be provided in surface-level parking spaces within the <br />motor-court area and in unassigned parking spaces within the parking structure. Therefore, <br />adequate on-site parking would be provided. <br /> <br />Bicycle Parking <br />The Design Guidelines require approximately 0.6 bicycle spaces per unit (long-term storage) <br />and two bicycle spaces for every 50 units (short-term storage/bike racks). For 360 units, 230 <br />bicycle spaces (214 long-term and 16 short-term) are required. The project would provide 230 <br />bicycle spaces within a designated area in the parking structure. Therefore, adequate on-site <br />bicycle parking would be provided. <br /> <br />Noise <br />External noise sources that could affect the subject site include traffic noise from Interstate 580 <br />to the north, Interstate 680 to the east, and adjacent City streets, and noise from adjacent land <br />uses (which consist mainly of office and commercial uses). Housing Element Mitigation <br />Measure 4.J-5c requires a demonstration that sensitive areas onsite would not be exposed to <br />traffic noise in excess of 65 dBL. The noise study prepared by the applicant (Exhibit B) <br />determined the sensitive areas to be studied were the courtyards and rooftop deck. The noise <br />study concluded those areas would not be exposed to noise levels above 60 dBL provided a <br />sound barrier is installed around the perimeter of the roof top deck area. That barrier may <br />include decorative glass complementary to the building design. A condition of approval has <br />been included requiring this barrier be shown on the plans submitted for permits. <br /> <br />Housing Element Mitigation Measure Mitigation Measure 4.J-5b, requires a demonstration the <br />project would meet the City’s 45 dBL interior noise standard. It is anticipated normal <br />construction methods and requirements would allow the proposed building to comply with this <br />standard. A condition of approval requires information be submitted at the building permit plan <br />check stage sufficient to determine this standard would be met. <br /> <br />Noise Impacts on Adjacent Properties <br />The project would generate added urban noise, such as traffic, loading and unloading of <br />delivery trucks, etc. However, given the existing noise levels produced by nearby street and <br />freeway traffic and the existing commercial and office uses in the area, noise levels would not <br />change substantially from that currently experienced in the area . Construction equipment <br />would be required to meet DMV noise standards and be equipped with muffling devices. Once <br />constructed, the operation of the project would be required to meet the City’s noise ordinance, <br />which stipulates the project cannot produce a noise level more than 70 dBA at any point <br />outside of the property plane. The project, based on its proposed residential use is not <br />expected to generate any unusual sources of noise. <br />