My WebLink
|
Help
|
About
|
Sign Out
04
City of Pleasanton
>
CITY CLERK
>
AGENDA PACKETS
>
2022
>
110122
>
04
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/26/2022 3:38:18 PM
Creation date
10/26/2022 3:37:57 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
AGENDA REPORT
DOCUMENT DATE
11/1/2022
DESTRUCT DATE
15Y
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
61
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ordinance No. 2241 <br /> Page 16 of 60 <br /> R313.2 Large One-and Two-Family Dwelling Residential Sprinkler Systems. <br /> In addition to the requirements specified in R313.1,one-and two-family dwellings with a habitable floor <br /> area greater than 7,500 square feet shall have an automatic fire-sprinkler system designed to include all <br /> sprinklers within a compartment, up to a maximum of four sprinklers. <br /> 20.10.060 CRC Table R602.10.3(3)amended—Bracing Requirements based on Seismic Design <br /> Category. <br /> Table R602.10.3(3)is amended to read as follows: <br /> Table column title MINIMUM TOTAL LENGTH(FEET)OF BRACED WALL PANELS REQUIRED <br /> ALONG EACH BRACED WALL LINE is amended to add footnote"i". <br /> Footnote"i"is added,to read as follows: <br /> i. Method CS-SFB and Method GB are not permitted,and the use of Method PCP is limited to one- <br /> story single-family dwellings and accessory structures. <br /> 20.10.070 CRC Section R602.10.4.5 added—Limits on methods GB and PCP. <br /> Section R602.10.4.5 is added,to read as follows: <br /> Method GB is not permitted for use as intermittent braced wall panels,but gypsum board is <br /> permitted to be placed on the opposite side of the studs from other types of braced wall panel <br /> sheathing. The use of Method PCP is limited to one-story single-family dwellings and accessory <br /> structures. <br /> 20.10.080 CRC Section R902.1 amended—Roofing covering materials. <br /> Section R902.1 is amended to read as follows: <br /> R902.1 Roofing covering materials. <br /> Roofs shall be covered with materials as set forth in Sections R904 and R905. A minimum Class B <br /> roofing, listed and tested in accordance with UL 790 or ASTM E108, is required in the City of <br /> Pleasanton. <br />
The URL can be used to link to this page
Your browser does not support the video tag.