Attachment 1 Exhibit B <br /> an approved calculation method,then the local enforcing agency may grant a modification. <br /> The applicant shall comply with Section 4.106.5.2. <br /> Inactive Fuel Gas Infrastructure may be extended to spaces that are anticipated to qualify for the <br /> exceptions contained in this chapter. The inactive Fuel Gas Infrastructure shall not be activated,have a <br /> meter installed,or otherwise used unless the exemptions specified in this chapter have been confirmed as <br /> part of the issuance of a building permit. If the Fuel Gas Infrastructure is no longer serving one of the <br /> exceptions contained in this chapter, it shall either be capped,otherwise terminated,or removed by the <br /> entity previously entitled to the exemption, in a manner pursuant to all applicable Codes. <br /> Pleasanton shall have the authority to approve alternative materials,design and methods of construction <br /> or equipment per California Building Code Section 104. <br /> 20.26.260 Section 4.106.5.2 added—Requirements for combustion equipment. <br /> Section 4.106.5.2 is added to read as follows: <br /> 4.106.5.2 Requirements for combustion equipment. <br /> Where combustion equipment is allowed per Exceptions under 4.106.5.1,the construction drawings shall <br /> indicate electrical infrastructure and physical space accommodating the future installation of an electrical <br /> heating appliance in the following ways, as certified by a registered design professional or licensed <br /> electrical contractor: <br /> 1. Branch circuit wiring,electrically isolated and designed to serve all electrical heating <br /> appliances in accordance with manufacturer requirements and the California Electrical Code, <br /> including the appropriate voltage,phase, minimum amperage,and an electrical receptacle or <br /> junction box within five feet of the appliance that is accessible with no obstructions. <br /> Appropriately sized conduit may be installed in lieu of conductors;and <br /> 2. Labeling of both ends of the unused conductors or conduit shall be with"For Future <br /> Electrical Appliance"; and <br /> 3. Reserved circuit breakers in the electrical panel for each branch circuit,appropriately labeled <br /> (i.e., "Reserved for Future Electric Range"), and positioned on the opposite end of the panel <br /> supply conductor connection; and <br /> 4. Connected subpanels,panelboards, switchboards, busbars,and transformers shall be sized to <br /> serve the future electrical heating appliances. The electrical capacity requirements shall be <br /> adjusted for demand factors in accordance with the California Electric Code; and <br /> 5. Physical space for future electrical heating appliances, including equipment footprint,and if <br /> needed a pathway reserved for routing of ductwork to heat pump evaporator(s), shall be <br /> depicted on the construction drawings. The footprint necessary for future electrical heating <br /> appliances may overlap with non-structural partitions and with the location of currently <br /> designed combustion equipment. <br /> 20.26.270 Section 4.408 amended—Construction Waste Reduction,Disposal and Recycling. <br /> Section 4.408 is amended to read as follows: <br /> 4.408.1 Construction waste management.As provided in Municipal Code Chapter 9.21, "regulated <br /> projects"as defined therein shall comply with Municipal Code Chapter 9.21. Projects that are not <br /> regulated by Municipal Code Chapter 9.21 shall comply with CALGreen Section 4.408,as applicable. <br /> Page 44 of 60 <br />