My WebLink
|
Help
|
About
|
Sign Out
07
City of Pleasanton
>
CITY CLERK
>
AGENDA PACKETS
>
2022
>
101822
>
07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/12/2022 4:33:52 PM
Creation date
10/12/2022 4:33:25 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
AGENDA REPORT
DOCUMENT DATE
10/18/2022
EXPIRATION DATE
10/18/2022
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
80
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Attachment l Exhibit B <br /> 20.24.360 CFC Section 6004.1.8 added—Fire extinguishing systems. <br /> Section 6004.1.8 is added to read: <br /> 6004.1.8 Fire extinguishing systems.Buildings and covered exterior areas for storage and use areas of <br /> materials regulated by this Chapter shall be protected by an automatic fire sprinkler system in accordance <br /> with NFPA 13. The design of the sprinkler system for any room or area where highly toxic,toxic and <br /> moderately toxic gases are stored,handled or used shall be in accordance with Section 5004.5. <br /> 20.24.370 CFC Section 6004.1.9 added—Local gas shut off. <br /> Section 6004.1.9 is added to read: <br /> 6004.1.9 Local gas shut off.Manual activation controls shall be provided at locations near the point of <br /> use and near the source, as approved by the fire code official. The fire code official may require additional <br /> controls at other places, including,but not limited to,the entry to the building, storage or use areas,and <br /> emergency control stations.Manual activated shut-off valves shall be of a fail-safe-to-close design. <br /> 20.24.380 CFC Section 6004.1.10 added—Exhaust ventilation monitoring. <br /> Section 6004.1.10 is added to read: <br /> 6004.1.10 Exhaust ventilation monitoring.For highly toxic gases,toxic and moderately toxic gases <br /> exceeding minimum threshold quantities, a continuous monitoring system shall be provided to assure that <br /> the required exhaust ventilation rate is maintained. The system shall monitor actual air flow in the exhaust <br /> system. The monitoring system shall initiate a local alarm. The alarm shall be both visual and audible and <br /> shall be designed to provide warning both inside and outside of the interior storage,use,or handling area. <br /> 20.24.390 CFC Section 6004.1.11 added—Emergency response plan. <br /> Section 6004.1.11 is added to read: <br /> 6004.1.11 Emergency response plan.If the preparation of an emergency response plan for the facility is <br /> not required by any other law,responsible persons shall prepare, or cause to be prepared, and filed with <br /> the fire code official,a written emergency response plan. If the preparation of an emergency response <br /> plan is required by other law, a responsible person shall file a copy of the plan with the fire code official. <br /> 20.24.400 CFC Section 6004.1.12 added—Emergency Response Liaisons. <br /> Section 6004.1.12 is added to read: <br /> 6004.1.12 Emergency Response Liaisons.Responsible persons shall be designated and trained to be <br /> liaison personnel for the Livermore-Pleasanton Fire Department. There persons shall aid the Fire <br /> Department in preplanning emergency responses and understanding the materials and operations utilizing <br /> the gases. <br /> 20.24.410 CFC Section 6004.1.13 added— Emergency Drills. <br /> Section 6004.1.13 is added to read: <br /> Page 31 of 60 <br />
The URL can be used to link to this page
Your browser does not support the video tag.