Attachment 1 Exhibit B <br /> when administered by continuous inhalation for an hour, or less if death occurs within one hour,to albino <br /> rats weighing between 200 and 300 grams each. <br /> 20.24.145 CFC Chapter 6,Section 603.11 added-Multiple sources of non-utility electricity <br /> Section 603.11 is added to read: <br /> 603.11 Multiple sources of non-utility electricity. When a facility has more than one source of non- <br /> utility-based electrical utility power, including emergency and standby power systems,a written <br /> shutdown plan shall be provided. A copy of the plan will be posted at or near the main electrical panel in <br /> a location approved by the Fire Department.A copy of the plan will be provided in a format acceptable to <br /> the Fire Department. <br /> 20.24.150 CFC Section 611 added—Immersion Heaters. <br /> Section 611 is added to read: <br /> 605.18 Immersion Heaters.All electrical immersion heaters used in dip tanks, sinks,vats and similar <br /> operations shall be provided with approved over-temperature controls and low liquid level electrical <br /> disconnects. Manual reset of required protection devices shall be provided. <br /> 20.24.160 CFC Section 903.2 amended—Automatic Sprinkler Systems <br /> 903.2 is deleted and replaced with the following: <br /> 903.2 Where required. <br /> 1. Automatic fire extinguishing systems shall be provided in all new buildings and structures, <br /> including any detached or attached structure added to a parcel of land already containing automatic <br /> extinguishing system protected buildings. <br /> Exception: <br /> a. Detached U Occupancies, other than trash enclosures,that do not exceed 400 square feet of <br /> floor area. <br /> b. Trash enclosures that have been exempted by the fire code official or that meet the following <br /> conditions: <br /> i. The enclosure, including the cover and door, are constructed of non-combustible <br /> materials. <br /> ii. The enclosure does not exceed 180 square feet in size <br /> iii. The enclosure is stand-alone structure, be a minimum of 20 feet from adjacent <br /> buildings and a minimum of 10 feet from property line(s). <br /> iv. The enclosure is used exclusively for waste garbage contained within approved trash <br /> containers. No outdoor storage is permitted within the trash enclosure, <br /> c. Photo Voltaic Arrays covering parking stalls only. <br /> 2. Existing commercial or industrial buildings not currently provided with automatic fire extinguishing <br /> systems shall be provided with an automatic fire extinguishing systems as follows: <br /> Page 25 of 60 <br />