Laserfiche WebLink
WIND DESIGN SUBJECT TO DAMAGE <br /> FROM <br /> D e o 5. C = '41 �" w �' <br /> 3 U O °' g fY, z A z 1 <br /> `� °� " Cz7C7 . = wCz7if. dpGwOrC Afx NYC <br /> Ca7u .s 614 OQ W <br /> a <br /> Op d d 7E. 47X VOdWo v u zd .4 cg WZ� CA 3 .n AU k. <br /> rn 17. w <br /> See <br /> N/A mph NO NO NO D2 D`, Negligible N/A Henry 32° NO foot 2% 58.7° <br /> note g <br /> MANUAL J DESIGN CRITERIA° <br /> Winter Altitude correction Indoor Design Heating temperature <br /> Elevation Latitude heating Summer cooling factor design temperature difference <br /> temperature cooling <br /> 350 ft 38' 32° 93° 1.0 70° 75° 38° <br /> Wind Wind velocity Winter <br /> Cooling temperature difference velocity cooling Coincident wet bulb Daily range humidity Summer humidity <br /> heating <br /> 18° 15 mph 7.5 mph 67 35 75% 75% <br /> 1. For SI: 1 pound per square foot=0.0479 kPa, 1 mile per hour=0.447 m/s. <br /> 2. The weathering index for the City of Pleasanton is classified as"negligible". <br /> 3. The City of Pleasanton does not require additional depth of footing below finish grade. <br /> 4. The City of Pleasanton has a history of local subterranean termite damage. <br /> 5. The City of Pleasanton is in the 85 mph wind speed zone. <br /> 6. The outdoor design dry-bulb temperature for the City of Pleasanton was selected from the columns of 97'/2-percent values for winter from <br /> Appendix D of the 2018 International Plumbing Code. <br /> 7. The City of Pleasanton is in Seismic design categories D°,Dl,D2 and E. <br /> 8. The date of the City of Pleasanton's entry into the National Flood Insurance Program: May 5,1971. <br /> 9. The date(s)of the Flood Insurance Study:August 3,2009.The panel numbers of all currently effective FIRMs adopted by the <br /> City of Pleasanton,as amended: <br /> 10. Panel 06001C0304G;Panel 06001C0308G;Panel 06001C0309G;Panel 06001C0316G; Panel 06001C0317G;Panel <br /> 06001C0318G;Panel 06001 C0319G;Panel 06001 C0328G;Panel 06001 C0336G;Panel 06001 C0337G;Panel <br /> 06001 C0339G;Panel 06001 C0343G;Panel 06001 C0460G;Panel 06001 C0476G;Panel 06001C0480G;and Panel <br /> 06001C0485G. <br /> 11. The City of Pleasanton does not have a history of local damage from the effects of ice damming. <br /> 12. The City of Pleasanton selected the 100-year(99%)value on the National Climatic Data Center data table"Air Freezing Index-USA <br /> Method(Base 32°)"at www.ncdc.noaa.gov/fpsf.html. <br /> 13. The City of Pleasanton selected the mean annual temperature from the National Climatic Data Center data table"Air Freezing Index-USA <br /> Method(Base 32°F)"at www.ncdc.noaa.gov/fpsf.html. <br /> 14. No local historical data documenting structural damage to buildings due to topographic wind speed-up effects in the City of Pleasanton. <br /> 15. The City of Pleasanton is not in a Special Wind Region. <br /> 16. The City of Pleasanton is not in a Wind-borne debris zone. <br /> 17. The City of Pleasanton is using Table 1B for Pleasanton,CA from ACCA Manual J. <br /> 18. The City of Pleasanton does not have Ground Snow Loading. <br /> 20.10.050 CRC Section R313 amended-Automatic Fire Sprinkler Systems. <br /> Section 8313 is deleted in its entirety and amended to read as follows: <br /> R313.1 Automatic Fire Sprinkler Systems. <br /> An automatic residential fire sprinkler system shall be designed and installed in accordance with NFPA <br /> 13D in all new one-and two-family dwellings and townhouses. In addition,the fire-sprinkler system <br /> shall be designed and sprinklers shall be installed in the following locations: <br /> 1. Attic shall be provided with intermediate temperature-rated residential fire sprinklers for <br /> detection coverage,and located at a spacing equivalent to 30 feet by 30 feet centers and a <br /> maximum distance of 15 feet from outside walls. <br /> 2. Fire sprinklers shall be provided in garages. Fire sprinklers shall be intermediate rated,quick <br /> response type,with a maximum coverage area of 130 square feet per sprinkler. <br /> Page 15 of 60 <br />