My WebLink
|
Help
|
About
|
Sign Out
16
City of Pleasanton
>
CITY CLERK
>
AGENDA PACKETS
>
2022
>
081622
>
16
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/19/2022 9:24:42 AM
Creation date
8/19/2022 9:24:37 AM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
AGENDA REPORT
DOCUMENT DATE
8/16/2022
DESTRUCT DATE
15Y
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
() 5I N( E-PANIC- I (E) MULTI- FAMIL'( <br /> x i7TI7 i <br /> I . x i MTf • fi <br /> • I to io <br /> �� i <br /> • i X X x . <br /> - _ • 29 PARK1ti G SPAGES <br /> • - 9 (z ACCtSSIBLE SPACES)) <br /> 17/ <br /> 1 •� a <br /> czc <br /> A PARK <br /> w <br /> +/ lac- ��� ►+ <br /> // a oC <br /> 2 ' L_ a I-- <br /> ,Q • I \ co z <br /> •. iF(n)Pe•IGE • • • , <br /> • <br /> • .�(E)TR S,T' ' i • • •• <br /> • <br /> ' <br /> (E) SINGIt-FAMIL`( (e.. MULTI-fAMIL1 N <br /> Existing Facility Conditions <br /> As stated above, the City of Pleasanton retained the services of Jeff Katz Architecture <br /> (JKA) to provide a comprehensive analysis of the building and determine structural, <br /> mechanical, plumbing, electrical, and Americans with Disabilities Act (ADA) issues. <br /> Existing floor plans of the first and second floor are included as Attachment 9 to this <br /> report. In addition to the JKA assessment, staff consulted with the Building and Safety <br /> Division to understand minimum building and accessibility requirements. Not all elements <br /> of the facility would need to be upgraded to current building code requirements due to the <br /> historic nature of the facility and staff would continue to coordinate with the Building and <br /> Safety Division. <br /> The existing facility has been vacant since 2014 due to numerous building and life safety <br /> code deficiencies. The existing ramp and main building entrance are non-compliant, as <br /> are the existing restrooms. Many of the existing interior door openings are not adequate <br /> in width, clear floor space or level. The existing mechanical, electrical and plumbing <br /> systems require replacement to bring the facility up to operational, safety and code <br /> compliant standards. The existing structural system exhibits many deficiencies, including <br /> dry rot and material deficiencies throughout, inadequate connections of building framing <br /> to foundations and other miscellaneous deficiencies. <br /> The existing exterior siding, trim, roof, windows, deck material and deck railings/stairs <br /> would require major repair and/or replacement. The existing interior stairway is non- <br /> Page 5 of 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.