PRODUCT DESCRIPTIONSYMBOL <br />GATE VALVE <br />MASTER CONTROL VALVE <br />IRRIGATION LEGEND <br />EX. DOMESTIC WATER MAIN <br />FLOW SENSOR (SUB-METER) <br />ELECTRIC CONTROLLER <br />WIRELESS WEATHER/RAIN SENSOR <br />REMOTE CONTROL VALVE <br />DRIP ZONE CONTROL KIT <br />DRIP FLUSH VALVE <br />SHRUB BUBBLER <br />TREE BUBBLER <br />IRRIGATION SUPPLY LINE <br />IRRIGATION LATERAL LINE <br />SLEEVING <br />ELECTRICAL CONDUIT <br />SUBSURFACE DRIP LINE <br />CONTROLLER STATION NUMBER <br />CONTROL VALVE SIZE <br />C <br />R <br />GALLONS PER MINUTE THROUGH VALVE <br />BACKFLOW PREVENTION <br />DEVICE <br />sta <br />gpm <br />size <br />M <br />NIBCO-T113-1.25" <br />FEBCO-LF767FR-1" <br />SUPERIOR-3100-1" <br />IRRITROL-FS-B100 <br />IRRITROL-MC-18-E <br />IRRITROL-CL-100-WIRELESS <br />RAINBIRD-RWS-S-B-C-1401 <br />RAINBIRD-XCZ-PRB-100-COM <br />RAINBIRD-XCZ-PRB-100-COM <br />RAINBIRD-RWS-S-B-C-1401 <br />RAINBIRD-RWS-B-C-1404 <br />1120/SCHEDULE 40 PVC PIPE -18" COVER <br />1120/SCHEDULE 40 PVC PIPE -12" COVER <br />1120/SCHEDULE 40 PVC PIPE -24" COVER <br />1120/SCHEDULE 40 PVC ELECTRICAL CONDUIT -24" COVER <br />NETAFIM-TLRW-6-12 <br />1.IRRIGATION SYSTEM IS DESIGNED FOR A MAXIMUM OF 12 G.P.M. AT 60 P.S.I. STATIC PRESSURE. VERIFY PRESSURE OF 60 P.S.I. AT THE POINT OF CONNECTION <br />PRIOR TO BEGINNING THE INSTALLATION OF THE IRRIGATION SYSTEM. NOTIFY OWNERS REPRESENTATIVE OF ANY DISCREPANCIES IN PRESSURE. <br />2.NOTIFY OWNERS REPRESENTATIVE SIX (6) DAYS PRIOR TO INSTALLATION FOR A PRE-INSTALLATION CONFERENCE AND FIELD REVIEW COORDINATION FOR <br />TRENCH DEPTHS, ASSEMBLY REVIEW, PRESSURE TESTS, COVERAGE TESTS, PRE-MAINTENANCE AND FINAL REVIEWS. A CONTINUITY TEST WILL BE REQUIRED <br />FOR CONTROL WIRE STUBOUTS. NO SUBSTITUTIONS WILL BE ALLOWED WITHOUT PRIOR WRITTEN APPROVAL FROM THE OWNERS REPRESENTATIVE. <br />3.INSTALL CONTROLLER WHERE INDICATED. EXACT LOCATION OF CONTROLLER TO BE DETERMINED AT JOBSITE BY OWNERS REPRESENTATIVE. 120 VOLT <br />ELECTRICAL SUPPLY IS PROVIDED FOR IN IMMEDIATE VICINITY BY ELECTRICAL SECTION OF CONTRACT. MAKE FINAL 120 VOLT ELECTRICAL CONNECTION TO <br />CONTROLLER. USE THIN WALL METAL CONDUIT ABOVE GRADE. USE WATERPROOF CONNECTIONS FOR OUTDOOR INSTALLATION. PROGRAM CONTROLLER TO <br />NOT EXCEED MAXIMUM FLOW RATE STATED IN NOTE NO. 1. INSTALL PER MANUFACTURERS SPECIFICATIONS. INSTALL AS DETAILED. SEAL ALL CONDUIT HOLES <br />WITH SILICONE OR EQUAL. PROGRAM CONTROLLER TO IRRIGATE USING MULTIPLE REPEAT CYCLES OF SHORT DURATIONS. CARE SHALL BE TAKEN TO PREVENT <br />RUNOFF OF WATER AND SLOPE/SOIL EROSION DUE TO PROLONGED APPLICATIONS OF WATER. GROUNDING AND INSTALLATION SHALL BE IN ACCORDANCE WITH <br />MANUFACTURERS WRITTEN SPECIFICATIONS. <br />4.INSTALL ALL EQUIPMENT AS DETAILED. INSTALL R.C.V. ID TAGS MANUFACTURED BY T. CHRISTY ENT. STANDARD SIZE, 1-1/8" HOT STAMPED BLACK LETTERS ON <br />YELLOW BACKGROUND ON SOLENOID WIRES. LETTERS TO CONFORM TO CONTROLLER/STATION NUMBER. <br />5.HEADS SHALL HAVE RISER ASSEMBLIES AS DETAILED. <br />6.PIPE AND WIRING UNDER PAVEMENT SHALL BE INSTALLED AT A TWENTY-FOUR INCH (24") DEPTH BELOW GRADE. ALL WIRING UNDER PAVEMENT SHALL BE <br />INSTALLED IN PVC SCHEDULE 40 ELECTRICAL CONDUIT. ELECTRICAL CONDUIT SHALL EXTEND SIX INCHES (6") BEYOND EDGE OF PAVEMENT. INSTALL SAND FOR <br />BACKFILL IN VEHICULAR PAVEMENT AREAS TO 6" COVER ABOVE PIPE. SURROUND PIPE WITH SAND IN AREAS WHERE ROCKY TERRAIN IS ENCOUNTERED. <br />7.VALVE CONTROL WIRE SHALL BE MINIMUM NO. 14 AWG COPPER UL APPROVED FOR DIRECT BURIAL IN GROUND. CONNECT WIRES WITH 3M DBY CONNECTORS PER <br />MANUFACTURERS SPECIFICATIONS. EACH WIRE AT VALVES SHALL HAVE 24" EXCESS COILED LOOP IN VALVE BOXES. TAPE WIRES IN BUNDLES EVERY TEN FEET <br />IN PLANTING AREAS. <br />8.AT JOB COMPLETION, SUPPLY OWNER WITH TWO (2) KEYS FOR CONTROLLER. <br />IRRIGATION SYSTEM NOTES <br />C <br />R <br />C-1 <br />1 <br />1.00 <br />C-2 <br />1 <br />1.00 <br />PROPOSED <br />CONTROLLER <br />LOCATION PROVIDE <br />120 VAC ELECTRICAL <br />SOURCE <br />PROPOSED POINT OF CONNECTION <br />CUT INTO AND CONNECT TO <br />DOMESTIC SUPPLY LINE,VERIFY <br />LOCATION IN FIELD <br />IRRIGATION PLAN <br />L7.1 <br />SCALE: <br />1/16" = 1'-0" <br />dhd damir hurdich design <br />633 quarry rd. suite a <br />san carlos, ca 94070 <br />67 otsego avenue <br />san francisco, ca 94112 <br />tel.415.786.6427 <br />REVISIONS <br />DATE SET DH <br />1 <br />Ahmed Residence <br />4108 Foothill Road <br />Pleasanton, CA 94588 <br />02.04.22 PLANNING SUBMITTAL <br />05.03.22 REVISIONS <br />1