Laserfiche WebLink
limited to a water supply and water flow in conformance to the City's Fire <br /> Department Standards able to suppress a major fire. <br /> 98. FIRE HYDRANTS: Fire hydrants shall be installed at spacing not greater than <br /> 300 feet in industrial and commercial developments. Fire hydrants shall be <br /> installed at spacing not greater than 400 feet in residential developments. <br /> 99. FIRE LANE MARKING: On-site access ways, turn arounds, and internal drives <br /> shall be designated as fire lanes and identified as such by red curb striping and <br /> posted with signs at locations approved by the Fire Department. Signs shall be <br /> according to State standards and read "No Parking — Fire Lane" and must be <br /> shown on the plans. The red curb striping, sign location(s), and sign language <br /> shall be included in the building permit submittal for review and approval by the <br /> Livermore-Pleasanton Fire Department prior to building permit issuance. <br /> a. The following schedule for NO PARKING signs shall apply: <br /> Width Requirements <br /> 36 feet or greater No requirements <br /> Between 28 and 36 feet Post one side <br /> Between 20 and 28 feet Post both sides <br /> Less than 20 feet Not permitted <br /> Cul-de-Sac Not permitted <br /> 100. EMERGENCY VEHICLE ACCESS ROADS: Access roads shall have 13 feet, 6 <br /> inches unobstructed vertical clearance, 20 feet of unobstructed width (26 feet <br /> where occupied building floors exceed 30 feet height), and inside turning radius <br /> of 31 feet and outside turning radius of 51 feet. Unobstructed shall mean a clear <br /> travel way, excluding parking width, and designed for an emergency vehicle <br /> weight of 70,000 pounds under all weather conditions. Unobstructed width shall <br /> not include the width of rolled curbs, sidewalks, or non-drivable surfaces. All <br /> exterior portions of buildings must be within 200 feet of an access road. Yard <br /> and parking area may be able to be located farther than 200 feet from access <br /> roads, depending on the specific use. <br /> 101. FIRE VEHICLE TURNAROUNDS: Where Fire Department vehicle access <br /> through or around a site involves changes in direction or curves, inside radius of <br /> 45 feet and outside radius of 55 feet shall be provided to facilitate fire truck <br /> turning radius for entry and exit from the site. Dead-end access ways and <br /> internal drives shall not exceed 300 feet in length and shall terminate in cul-de- <br /> sacs no less than 96 feet in diameter or hammer-head (tee). Standards and <br /> options are available through the Livermore-Pleasanton Fire Department, Fire <br /> Prevention Bureau. <br /> 102. PREMISES IDENTIFICATION: Address numbers shall be installed on the front <br /> or primary entrance for all buildings. Minimum building address character size <br /> PUD-138 and VTM 8616 Planning Commission <br /> Page 25 of 30 <br />or to tract acceptance) <br /> 90. WARRANTY BOND: The applicant shall submit a one-year warranty bond in an <br /> amount of 10 percent of the full value of all required subdivision improvements <br /> PUD-138 and VTM 8616 Planning Commission <br /> Page 23 of 30 <br />ior to the approval of the improvement plans by the Director of <br /> PUD-138 and VTM 8616 Planning Commission <br /> Page 20 of 30 <br />homes connecting to these facilities (including the Golf <br /> PUD-138 and VTM 8616 Planning Commission <br /> Page 15 of 30 <br />ude that this finding can be made. <br />censed civil engineer, <br /> which include but is not limited to the type, location, and sizing calculations of the <br /> PUD-114-01M& P20-0995 Planning Commission <br /> Page 16 of 25 <br />d) individuals. <br /> PUD-114-01M& P20-0995 Planning Commission <br /> Page 3 of 25 <br />