PC-2021-11
City of Pleasanton
>
BOARDS AND COMMISSIONS
>
PLANNING
>
RESOLUTIONS
>
2020 - PRESENT
>
2021
>
PC-2021-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/25/2022 11:07:57 AM
Creation date
4/25/2022 11:07:19 AM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
RESOLUTIONS
DOCUMENT DATE
7/14/2021
DESTRUCT DATE
PERMANENT
DOCUMENT NO
PC-2021-11
NOTES
PUD-114-01M, P20-0995, GUY HOUSTON, RESURRECTION GREEK ORTHODOX XHURXH, MAJOR MOD TO PUD
NOTES 2
MINOR SUBDIVISION, 11300 DUBLIN CANYON RD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
69. DAMAGE TO EXISTING PUBLIC AND PRIVATE IMPROVEMENTS: The applicant shall <br /> repair damage to existing public and private improvements on and near the project site <br /> and along the haul route at their full expense caused by construction activities as <br /> determined and to the satisfaction of the Director of Engineering/City Engineer and prior <br /> to the City Council acceptance of public improvements. (Address this condition prior to <br /> Occupancy Permit issuance.) <br /> 70. AS-BUILT DRAWINGS: The applicant's California licensed civil engineer shall submit <br /> signed and stamped as-built drawings and AutoCAD files for the construction of the <br /> public improvements and stormwater treatment system subject to the review and <br /> approval of the Director of Engineering/City Engineer and prior to the release of the <br /> performance and labor and materials bond. (Address this condition prior to Occupancy <br /> Permit issuance.) <br /> 71. SANITARY SEWER CLEANOUT: A sanitary sewer service lateral with a two-way <br /> cleanout shall be installed at the back of the sidewalk or curb, whichever is applicable, at <br /> each lot of record within the development in compliance with the City Standard <br /> Specifications and Details in effect at the time of issuance of the encroachment, grading, <br /> or subdivision permit, whichever occurs first, unless otherwise approved by the Director <br /> of Engineering/City Engineer. (Address this condition prior to Building Permit issuance.) <br /> 72. SANITARY SEWER CONNECTIONS: The applicant shall provide each lot, parcel of <br /> land, or building with an independent connection to the public sanitary sewer main as <br /> provided for in the Municipal Code. (Address this condition prior to Building Permit <br /> issuance.) <br /> 73. WATER LATERALS: The applicant shall provide each lot, parcel of land, or building with <br /> an independent connection to the public water main as provided for in the Municipal <br /> Code. (Address this condition prior to Building Permit issuance.) <br /> 74. WATER METERS (NON-RESIDENTIAL): The applicant shall provide a separate water <br /> meter and water system for domestic and irrigation purposes subject to the review and <br /> approval of the Director of Operations and Water Utilities. The applicant shall use <br /> recycled water for landscape irrigation as determined by the Director of Operations and <br /> Water Utilities. (Address this condition prior to Building Permit issuance.) <br /> 75. JOINT UTILITY TRENCH: All dry utilities (electric power distribution, gas distribution, <br /> communication service, cable television, street lights and alarm systems) required to <br /> serve an existing or new development shall be installed in underground conduit in a joint <br /> utility trench subject to the review and approval of the Director of Engineering/City <br /> Engineer and prior to City council acceptance of public improvements. (Address this <br /> condition prior to Building Permit issuance.) <br /> 76. PARCEL MAP APPROVAL: The applicant shall submit to the Engineering Department <br /> one completely signed Mylar copy of the parcel map, one signed copy of the <br /> improvement plans, one signed copy of the Subdivision Agreement, and one signed copy <br /> PUD-114-01M&P20-0995 Planning Commission <br /> Page 14 of 25 <br /> applicant shall bear all costs for <br /> work related to this condition by their geotechnical engineer. (Address this condition prior <br /> to Grading and/or Building Permit issuance.) <br /> PUD-114-01M& P20-0995 Planning Commission <br /> Page 13 of 25 <br /> and April 15, <br /> and from August 15 through October 30, in order to avoid take of non-volant <br /> (non—flying or inactive, either young, or seasonally torpid) individuals. <br /> PUD-114-01M& P20-0995 Planning Commission <br /> Page 3 of 25 <br />