My WebLink
|
Help
|
About
|
Sign Out
ORD 2223
City of Pleasanton
>
CITY CLERK
>
ORDINANCES
>
2201 - 2300
>
ORD 2223
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2023 4:22:55 PM
Creation date
10/11/2021 4:34:43 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
ORDINANCES
DOCUMENT DATE
10/5/2021
DESTRUCT DATE
PERMANENT
NOTES
PUD-140 2207 MARTIN AVE
Tags
Ordinance
Description:
Ordinance
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
that must implement one of the following site design measures to address pollution from storm <br /> water runoff: <br /> a. Direct roof runoff into cisterns or rain barrels for use <br /> b. Direct roof runoff onto vegetated areas <br /> c. Direct runoff from sidewalks, walkways, and/or patios onto vegetated areas <br /> d. Direct runoff from driveways/uncovered parking lots onto vegetated areas <br /> e. Construct sidewalks, walkways, and/or patios with permeable surfaces <br /> f. Construct driveways, and/or uncovered parking areas with permeable surfaces <br /> The applicant shall indicate on the plans which site design measure will be implemented. Project <br /> specific condition. <br /> 35. PARALLEL SANITARY SEWER LATERALS. According to Sheet 2 of the PUD plans (Reference <br /> 2), a new lateral is proposed for Parcel 1 immediately adjacent to and parallel with the existing <br /> lateral stub installed with Tract 6596 for Parcel 2. City Standard Specification Section 11-03A.2 <br /> requires free working space along the sides of parallel pipes of not less than 12" plus the diameter <br /> of the pipe. The centerline-to-centerline separation must therefore be not less than 6" (half pipe) + <br /> 12" + 12" + 6" (half pipe) = 36" or 3' minimum. Since the Parcel 1 lateral will be very close to the <br /> common property line separating Parcel 2 and the neighbor to the north, the design may need to <br /> incorporate some angle fittings to allow the lateral to eventually align with the center of the <br /> proposed 10'-wide private utility easement. Project specific condition. <br /> 36. SUBDIVISION IMPROVEMENT AGREEMENT. As indicated on Sheet 3 of the VTPM (Reference <br /> 3), the Dennis Drive frontage must be fully developed including road widening and dedication of <br /> public right-of-way and easement for public services prior to occupancy of the new home on Parcel <br /> A. Said work shall be guaranteed by a Subdivision Improvement Agreement drafted by the City <br /> Attorney with sufficient financial security to assure completion of the required work by the <br /> subdivider. Project specific condition. <br /> 37. MONUMENTS. The Parcel Map shall include two survey monuments (iron pipe with cap) where the <br /> proposed property line between Parcel 1 and Parcel 2 meets the north and south property lines. In <br /> accordance with §66495-66497 of the California Government Code, the Final Parcel Map must <br /> include sufficient durable survey monuments to allow the subdivision to be retraced. Project <br /> specific condition. <br /> 38. UNDERGROUND UTILITIES FOR NEW HOUSE. All new utilities to serve the proposed house <br /> shall be installed underground. Project specific condition. <br /> 39. UTILITY UNDERGROUNDING ON MARTIN AVENUE. The existing overhead joint pole utilities <br /> along the Martin Avenue frontage shall either be placed underground by the applicant, or the <br /> applicant shall deposit funds with the City in an amount proportional to the applicant's share of the <br /> total cost of a future City-sponsored undergrounding project. The existing joint pole utilities extend <br /> on the west side of Martin Avenue from south of Trenery Drive to the northern cul-de-sac bulb. The <br /> applicant's contribution will be $55,560. Project specific condition. <br /> 40. DESIGN PER CITY STANDARDS: All public improvements shall be designed in compliance with <br /> the City Standard Specifications and Details in effect at the time of the issuance of the <br /> encroachment, grading, or subdivision permit, whichever occurs first. <br /> 41. CONDITIONS OF APPROVAL: The Conditions of Approval shall be depicted on a plan sheet(s) <br /> in the improvement plans. <br /> PUD-140 & P21-0079 City Council <br /> Page 6 of 13 <br />
The URL can be used to link to this page
Your browser does not support the video tag.