My WebLink
|
Help
|
About
|
Sign Out
PC-2018-08
City of Pleasanton
>
BOARDS AND COMMISSIONS
>
PLANNING
>
RESOLUTIONS
>
2010-2019
>
2018
>
PC-2018-08
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/27/2021 1:33:54 PM
Creation date
7/27/2021 1:33:24 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
RESOLUTIONS
DOCUMENT DATE
4/25/2018
DESTRUCT DATE
PERMANENT
DOCUMENT NO
PC-2018-08
NOTES
PUD-125, PUD for Carpenter's Training Trust Fund (CTC), 2350 Santa Rita Rd
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Engineering Department <br /> 38. The applicant shall slurry seal the length and width of the driving vehicle lane that is <br /> being impacted by the installation of the new 8-inch diameter sewer main along Santa <br /> Rita Road. This shall be depicted in the plans submitted for issuance of a building <br /> permit and is subject to review and approval by the City Engineer. <br /> 39. The applicant shall design DMA 5 without the 10-inch diameter storm drain bypass pipe <br /> for bioswale BMP 5, as shown in the preliminary stormwater quality control plan on <br /> sheet C5 in Exhibit B. The revision shall be a part of the plans submitted for issuance of <br /> a building permit and is subject to review and approval by the City Engineer. <br /> 40. The applicant shall install a new sewer manhole at the new 6-inch diameter sewer <br /> lateral connection point to the City sewer main. This shall be depicted in the plans <br /> submitted for issuance of a building permit and is subject to review and approval by the <br /> City Engineer. <br /> 41. The applicant shall install a new sewer manhole where the new 8-inch diameter sewer <br /> main connects to the existing city sewer main along Santa Rita Road. This shall be <br /> depicted in the plans submitted for issuance of a building permit and is subject to review <br /> and approval by the City Engineer. <br /> 42. The applicant shall install catch basin inserts (5 millimeter mesh screens) for trash <br /> capture, approved by the State Water Resources Control Board, on all bioswale <br /> overflow outlet risers. This shall be depicted in the plans submitted for issuance of a <br /> building permit and is subject to review and approval by the City Engineer. <br /> 43. The applicant shall abandon all unused utility stubs in compliance with the latest City <br /> standards. This shall be depicted in the plans submitted for issuance of a building <br /> permit and is subject to review and approval by the City Engineer. <br /> 44. The applicant shall submit potable water, storm sewer, and sanitary sewer demand <br /> calculations to the City for review and acceptance. The calculations shall be provided <br /> with the plans submitted for issuance of a building permit and is subject to review and <br /> approval by the City Engineer. <br /> 45. The applicant shall repair the uneven sidewalk at the three locations located along the <br /> project frontage. The locations include a Pacific Bell Utility Box near an existing fire <br /> hydrant, uplifted sidewalk near the north side of southernmost driveway, and uplifted <br /> sidewalk near a street tree. This shall be depicted in the plans submitted for issuance of <br /> a building permit and is subject to review and approval by the City Engineer. <br /> 46. The applicant shall install one tree per tree well within the two existing tree wells that <br /> are missing trees along the sidewalk fronting the property. The size and species of the <br /> trees shall be subject to the City Landscape Architect's review and approval. This shall <br /> be depicted in the plans submitted for issuance of a building permit and is subject to <br /> review and approval by the City Engineer. <br /> PUD-125, 2350 Santa Rita Road Planning Commission <br /> Page 8 of 21 <br /> All heating, ventilation, and air conditioning (HVAC) equipment, satellite receiving <br /> stations, etc., shall be located within the building's roof-equipment wells, and shall <br /> project no higher than a horizontal plane defined by the top-edge of the equipment <br /> PUD-125, 2350 Santa Rita Road Planning Commission <br /> Page 3 of 21 <br />