Laserfiche WebLink
City of Pleasanton–10x Genomics Project Environmental Checklist and <br />Initial Study/Mitigated Negative Declaration Environmental Evaluation <br /> <br /> <br />FirstCarbon Solutions 71 <br />Https://adecinnovations.sharepoint.com/sites/PublicationsSite/Shared Documents/Publications/Client (PN-JN)/2148/21480024/ISMND/wp/21480024 10x Genomics Project Full Screencheck ISMND.docx <br />iv) Landslides? <br />Less than significant impact. According to the General Plan and Geotechnical Investigation, the <br />project site is not located in an area that is at risk of earthquake-induced landslides.46,47 The project <br />site does not contain steep slopes that would be susceptible to landslides. The elevation of the <br />project site ranges from 340 to 350 feet, with a gentle slope to the east, toward the center of the <br />project site.48 Because the proposed project is not located in an area at risk of landslides and does <br />not contain steep slopes and is not adjacent to any steep slopes, the project site is not at risk of <br />landslides. Impacts would be less than significant. <br />b) Result in substantial soil erosion or the loss of topsoil? <br />Less than significant impact. Construction of the proposed project would involve site preparation, <br />grading, and construction activities that would disturb soils on-site and could result in erosion. <br />Because the proposed project would disturb more than 1 acre of land, the proposed project would <br />be required to adhere to the National Pollutant Discharge Elimination System (NPDES) General <br />Construction Permit, which contains requirements for erosion control of exposed soils during <br />construction, including implementation of a Storm Water Pollution Prevention Plan (SWPPP). The <br />SWPPP must identify potential sources of erosion or sedimentation that may be reasonably expected <br />to affect the quality of stormwater discharges, and is also required to identify BMPs to ensure the <br />reduction of these pollutants during stormwater discharges. Prior to construction grading, the <br />project Applicant would file a Notice of Intent to comply with the NPDES General Permit issued to <br />the Regional Water Quality Control Board (RWQCB) and would prepare the SWPPP, including the <br />identification of specific measures to minimize and control construction and post-construction <br />runoff to the maximum extent practicable. <br />BMPs that would be implemented include but are not limited to source control measures such as <br />labeling on-site inlets, landscaping that retains existing vegetation and minimizes pesticides and <br />fertilizers, efficient irrigation system, measures to prevent stormwater runoff from dumpsters and <br />recycling containers, temporary and permanent erosion control measures, use of sediment controls <br />or filtration to remove sediment when dewatering, and pollutant discharge control and prevention <br />measures. Additionally, the proposed project would utilize bioretention areas to treat stormwater. <br />Implementation of these BMPs would ensure that construction and operation of the proposed <br />project do not result in substantial erosion. <br />The proposed project would be required to comply with the CBC and with City Municipal Code <br />requirements pertaining to grading and excavation in effect at the time of project approval. The <br />proposed project would also be required to comply with the policies in the Public Safety Element of <br />the General Plan designed to minimize the risk of soil erosion and further mitigate its effects, <br />including Goal 1 Policy 2, which requires an investigation to be conducted for potential seismic <br /> <br />46 Forrest, T.M., Gildea, P., Flessas, M.G. 2020. Geotechnical Investigation, 10x Genomics Building 1, 1701 Springdale Avenue, <br />Pleasanton California, Figure 6, Regional Seismic Hazard Zones Map. December 3. <br />47 City of Pleasanton. 2009. Pleasanton General Plan 2005-2025, Chapter 5, Public Safety Element, Figure 5-1, Landslide Zones. <br />Website: https://www.cityofpleasantonca.gov/civicax/filebank/blobdload.aspx?BlobID=23899. Accessed February 2, 2021. <br />48 Forrest, T.M., Gildea, P., Flessas, M.G. 2020. Geotechnical Investigation, 10x Genomics Building 1, 1701 Springdale Avenue, <br />Pleasanton California. December 3.