Laserfiche WebLink
99. FIRE SPRINKLERS: Automatic fire sprinklers shall be installed in all occupancies in <br /> accordance with the 2016 Pleasanton Building, Fire and Residential Codes with local <br /> amendments and ordinances. <br /> 100. WILDLAND FIRE MANAGEMENT PLAN: Fire Fuel management provisions of the <br /> Wildland Fire Management Plan shall be enforced year-round. (Project Specific <br /> Condition) <br /> 101. FIRE PROTECTION FACILITIES: Prior to any construction framing, the applicant shall <br /> provide adequate fire protection facilities, including, but not limited to a water supply and <br /> water flow in conformance to the City's Fire Department Standards able to suppress a <br /> major fire. <br /> 102. HAZARDOUS MATERIALS: Should any operation or business activity involve the use, <br /> storage or handling of hazardous materials, the firm shall be responsible for contacting <br /> the Livermore-Pleasanton Fire Department prior to commencing operations. Please <br /> contact the Hazardous Materials Coordinator at 925/454-2361. <br /> 103. FIRE LANE MARKING: On-site access ways, turn arounds, and internal drives shall be <br /> designated as fire lanes and identified as such by red curb striping and posted with signs <br /> at locations approve by the Fire Department. Signs shall be according to State standards <br /> and read "No Parking — Fire Lane" and must be shown on the plans. The red curb <br /> striping, sign location(s), and sign language shall be included in the building permit <br /> submittal for review and approval by the Livermore-Pleasanton Fire Department prior to <br /> building permit issuance. <br /> a. The following schedule for NO PARKING signs shall apply: <br /> Width Requirements <br /> 36 feet or greater No requirements <br /> Between 28 and 36 feet Post one side <br /> Between 20 and 28 feet Post both sides <br /> Less than 20 feet Not permitted <br /> Cul-de-Sac Not permitted <br /> 104. EMERGENCY VEHICLE ACCESS ROADS: Access roads shall have 13 feet, 6 inches <br /> unobstructed vertical clearance, 20 feet of unobstructed width (26 feet where occupied <br /> building floors exceed 30 feet height), and inside turning radius of 31 feet and outside <br /> turning radius of 51 feet. Unobstructed shall mean a clear travel way, excluding parking <br /> width, and designed for an emergency vehicle weight of 70,000 pounds under all <br /> weather conditions. Unobstructed width shall not include the width of rolled curbs, <br /> sidewalks, or non-drivable surfaces. All exterior portions of buildings must be within 200 <br /> feet of an access road. Yard and parking area may be able to be located farther than <br /> 200 feet from access roads, depending on the specific use. <br /> 105. FIRE VEHICLE TURNAROUNDS: Where Fire Department vehicle access through or <br /> around a site involves changes in direction or curves, inside radius of 45 feet and <br /> outside radius of 55 feet shall be provided to facilitate fire truck turning radius for entry <br /> and exit from the site. Dead-end access ways and internal drives shall not exceed 300 <br /> PUD-135 City Council <br /> Page 18 of 23 <br />