Ordinance No. 2197 <br /> Exhibit B <br /> Page 21 <br /> CHAPTER 60 <br /> HIGHLY TOXIC AND TOXIC MATERIALS <br /> AND MODERATELY TOXIC GASES INCLUDING THOSE USED AS REFRIGERANTS <br /> 20.24.290 CFC Section 6004.1 amended — General. <br /> Section 6004.1 is hereby amended, and Table 6004.1 is added to read as follows: <br /> 6004.1 General. Materials that are stored and used as a gas whether or not the material meets <br /> the definition of a compressed gas, and that meet the definition of a highly toxic, toxic or <br /> moderately toxic gas shall comply with Section 6004. <br /> Performance based design alternatives may be used for refrigeration systems. <br /> Moderately toxic gases with an LC50 less than or equal to 3,000 parts per million shall comply with <br /> the requirements for toxic gases in Sections 6004.2.2.1 through 6004.2.2.10.4. <br /> Moderately toxic gases with an LC50 more than 3000 parts per million but not greater than 5000 <br /> parts per million and exceeding the maximum threshold quantity, as determined by Section <br /> 6004.1.6, shall comply with the requirements for toxic gases in Sections 6004.2.2.1 through <br /> 6004.2.2.7. <br /> The minimum threshold quantity for highly toxic, toxic and moderately toxic gases, vapors and <br /> mists for indoor and exterior storage and use are set forth in Table 6004.1. <br /> Table 6004.1 <br /> Minimum Threshold Quantities for Highly Toxic, Toxic and Moderately Toxic Gases <br /> Highly Toxic 0 cubic feet <br /> Toxic 10 cubic feet <br /> Moderately Toxic 20 cubic feet <br /> 20.24.300 CFC Section 6004.1.2 amended — Gas Cabinets. <br /> Section 6004.1 is hereby amended as follows: <br /> 6004.1.2 Gas cabinets. Gas cabinets containing highly toxic, toxic or moderately toxic gases <br /> shall comply with Section 5003.8.6 and the following requirements: <br /> [balance to remain the same] <br /> 20.24.310 CFC Section 6004.1.3 amended — Exhausted Enclosures. <br /> Section 6004.1.3 is hereby amended as follows: <br /> 6004.1.2 Exhausted enclosures. Exhausted enclosures containing highly toxic, toxic or <br /> moderately toxic gases shall comply with Section 5003.8.5 and the following requirements: <br /> [balance to remain the same] <br /> 20.24.320 CFC Sections 6004.1.4 added —Automatic shut-off valve. <br /> Section 6004.1.4 is added to read: <br /> 6004.1.4 Automatic shut-off valve. An automatic shut-off valve, which is of a fail-safe to close <br /> design, shall be provided to shut off the supply of highly toxic gases as close as possible to the <br /> supply container for any of the following: <br /> 1. Activation of a manual fire alarm system. <br /> 2. Activation of the gas detection system. <br />