Ordinance No. 2197 <br /> Exhibit B <br /> Page 17 <br /> 20.24.110 CFC Chapter 2 Definitions amended — Hazardous Materials. <br /> The definition of Hazardous Materials is amended as follows: <br /> HAZARDOUS MATERIALS. Those chemicals or substances which are physical hazards or <br /> health hazards as defined and classified in this chapter and/or are compressed gases, whether <br /> the materials are in usable or waste condition. <br /> 20.24.120 CFC Chapter 2 Definitions amended — Health Hazard. <br /> The definition of Health Hazard is amended as follows: <br /> HEALTH HAZARD. A classification of chemical for which there is statistically significant evidence <br /> that acute or chronic health effects are capable of occurring in exposed persons. The term "health <br /> hazard" includes chemicals that are moderately toxic, toxic, highly toxic, or corrosive. <br /> 20.24.130 CFC Chapter 2 Definitions added — Maximum Threshold Quantity <br /> The definition of Maximum Threshold Quantity is added as follows: <br /> MAXIMUM THRESHOLD QUANTITY. The following formula shall be used to calculate the <br /> maximum threshold quantity for toxic, highly toxic, and moderately toxic gases: <br /> Max TQ (lbs) = LC50 (ppm) x 2 lb. <br /> For gas mixtures containing one or more toxic, highly toxic or moderately toxic components, the <br /> LC50 shall be calculated using CGA Standards P-20 and P-23. <br /> 20.24.140 CFC Chapter 2 Definitions added — Moderately Toxic Gas <br /> The definition of Moderately Toxic Gas is added as follows: <br /> MODERATELY TOXIC GAS. A chemical or substance that has a medial lethal concentration <br /> (LC50) in air of more than 2,000 parts per million but not more than 5,000 parts per million by <br /> volume of gas or vapor, when administered by continuous inhalation for an hour, or less if death <br /> occurs within one hour, to albino rats weighing between 200 and 300 grams each. <br /> 20.24.150 CFC Section 605.18 added — Immersion Heaters. <br /> Section 605.18 is added to read: <br /> 605.18 Immersion Heaters. All electrical immersion heaters used in dip tanks, sinks, vats and <br /> similar operations shall be provided with approved over-temperature controls and low liquid level <br /> electrical disconnects. Manual reset of required protection devices shall be provided. <br /> 20.24.160 CFC Section 903.2 amended —Automatic Sprinkler Systems <br /> 903.2 is deleted and replaced with the following: <br /> 903.2 Where required. <br /> 1. Automatic fire extinguishing systems shall be provided in all new buildings and structures, <br /> including any detached or attached structure added to a parcel of land already containing <br /> automatic extinguishing system protected buildings. <br /> Exception: <br /> a. Detached U Occupancies, other than trash enclosures, that do not exceed 400 square <br /> feet of floor area. <br />