• <br /> Ordinance No. 2197 <br /> Exhibit B <br /> Page 9 <br /> For SI: 1 pound per square foot= 0.0479 kPa, 1 mile per hour= 0.447 m/s. <br /> a. The weathering index for the City of Pleasanton is classified as "negligible". <br /> b. The City of Pleasanton does not require additional depth of footing below finish grade. <br /> c. The City of Pleasanton has a history of local subterranean termite damage. <br /> d. The City of Pleasanton is in the 85 mph wind speed zone. <br /> e. The outdoor design dry-bulb temperature for the City of Pleasanton was selected from the columns of <br /> 971/2-percent values for winter from Appendix D of the 2018 International Plumbing Code. <br /> f. The City of Pleasanton is in Seismic design categories Do, D,, 02 and E. <br /> g. The date of the City of Pleasanton's entry into the National Flood Insurance Program: May 5, 1971. <br /> The date(s) of the Flood Insurance Study: August 3, 2009. The panel numbers of all currently <br /> effective FIRMs adopted by the City of Pleasanton, as amended: <br /> Panel 06001C0304G; Panel 06001 C0308G; Panel 06001C0309G; Panel 06001C0316G; Panel <br /> 06001C0317G; Panel 06001C0318G; Panel 06001C0319G; Panel 06001 C0328G; Panel <br /> 06001C0336G; Panel 06001C0337G; Panel 06001 C0339G; Panel 06001 C0343G; Panel <br /> 06001C0460G; Panel 06001C0476G; Panel 06001 C0480G; and Panel 06001C0485G. <br /> h. The City of Pleasanton does not have a history of local damage from the effects of ice damming. <br /> i. The City of Pleasanton selected the 100-year(99%) value on the National Climatic Data Center data <br /> table "Air Freezing Index- USA Method (Base 32°)" at www.ncdc.noaa.gov/fpsf.html. <br /> j. The City of Pleasanton selected the mean annual temperature from the National Climatic Data Center <br /> data table"Air Freezing Index-USA Method (Base 32°F)" at www.ncdc.noaa.gov/fpsf.html. <br /> k. No local historical data documenting structural damage to buildings due to topographic wind speed- <br /> up effects in the City of Pleasanton. <br /> I. The City of Pleasanton is not in a Special Wind Region. <br /> m. The City of Pleasanton is not in a Wind-borne debris zone. <br /> n. The City of Pleasanton is using Table 1B for Pleasanton, CA from ACCA Manual J. <br /> o. The City of Pleasanton does not have Ground Snow Loading. <br /> 20.10.050 CRC Section R313 amended —Automatic Fire Sprinkler Systems. <br /> Section R313 is deleted in its entirety and amended to read as follows: <br /> R313.1 Automatic Fire Sprinkler Systems. An automatic residential fire sprinkler system shall <br /> be designed and installed in accordance with NFPA 13D in all new one- and two-family dwellings <br /> and townhouses. In addition, the fire-sprinkler system shall be designed and sprinklers shall be <br /> installed in the following locations: <br /> 1. Attic shall be provided with intermediate temperature-rated residential fire sprinklers for <br /> detection coverage, and located at a spacing equivalent to 30 feet by 30 feet centers and <br /> a maximum distance of 15 feet from outside walls. <br /> 2. Fire sprinklers shall be provided in garages. Fire sprinklers shall be intermediate rated, <br /> quick response type, with a maximum coverage area of 130 square feet per sprinkler. <br /> R313.2 Large One- and Two-Family Dwelling Residential Sprinkler Systems. In addition to <br /> the requirements specified in R313.1, one- and two- family dwellings with a habitable floor area <br /> greater than 7,500 square feet shall have an automatic fire-sprinkler system designed to include <br /> all sprinklers within a compartment, up to a maximum of four sprinklers. <br /> 20.10.060 CRC Table R602.10.3(3)amended—Bracing Requirements based on Seismic <br /> Design Category. <br /> Table R602.10.3(3) is amended to read as follows: <br /> Table column title MINIMUM TOTAL LENGTH (FEET) OF BRACED WALL PANELS REQUIRED <br /> ALONG EACH BRACED WALL LINE is amended to add footnote "g". <br />