My WebLink
|
Help
|
About
|
Sign Out
ORD 2197
City of Pleasanton
>
CITY CLERK
>
ORDINANCES
>
2101 - 2200
>
ORD 2197
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2023 4:22:26 PM
Creation date
10/23/2019 12:23:28 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
ORDINANCES
DOCUMENT DATE
10/15/2019
DESTRUCT DATE
PERMANENT
NOTES
BUILDING CODE
Tags
Ordinance
Description:
Ordinance
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ordinance No. 2197 <br /> Exhibit B <br /> Page 5 <br /> 20.08.040 CBC Section 903 amended —Automatic Sprinkler Systems. <br /> Section 903 of the California Building Code 2019 Edition, (24 C.C.R. Part 2), and including by <br /> reference the International Building Code, 2018 Edition is amended to read as shown in section <br /> 903 of the Pleasanton Fire Code (PMC Chapter 20.24). <br /> 20.08.050 CBC Section 904 amended —Alternative Automatic Fire-Extinguishing <br /> Systems. <br /> Section 904 of the California Building Code 2019 Edition, (24 C.C.R. Part 2), and including by <br /> reference the International Building Code, 2018 Edition is amended to read as shown in section <br /> 904 of the Pleasanton Fire Code (PMC Chapter 20.24). <br /> 20.08.060 CBC Section 1505 amended — Fire Classification. <br /> Table 1505.1 Minimum Roof Coverings Classification is deleted, and Section 1505.1 is amended <br /> to add the following paragraph to read as follows: <br /> 1505.1 General. Roof coverings shall have a Class B or higher fire resistance rating for all <br /> buildings regardless of type of construction. <br /> 20.08.070 CBC Section 1705.3 amended — Concrete Construction. <br /> Section 1705.3 Exception 1 is amended to read as follows: <br /> 1705.3 Concrete Construction. The special inspections and verifications for concrete <br /> construction shall be as required by this section and Table 1705.3. <br /> Exception: Special inspections shall not be required for isolated spread concrete footings of <br /> buildings three stories or less above grade plane that are fully supported on earth or rock, <br /> where the structural design of the footing is based on a specified compressive strength, f'c, no <br /> greater than 2,500 pound per square inch (psi) (17.2 Mpa). <br /> 20.08.080 CBC Section 1905.1.7 amended —ACI 318 section 14.1.4. <br /> Section 1905.1.7 is amended to read as follows: <br /> 1905.1.7 ACI 318, Section 14.1.4. Delete ACI 318, Section 14.1.4, and replace with the <br /> following: <br /> 14.1.4 - Plain concrete in structures assigned to seismic design category C, D, E or F. <br /> 14.1.4.1- Structures assigned to Seismic Design Category C, D, E or F shall not have elements <br /> of structural plain concrete, except as follows: <br /> a) (Intentionally left blank) <br /> b) Isolated footings of plain concrete supporting pedestals or columns are permitted, <br /> provided the projection of the footing beyond the face of the supported member does <br /> not exceed the footing thickness. <br />
The URL can be used to link to this page
Your browser does not support the video tag.