My WebLink
|
Help
|
About
|
Sign Out
07
City of Pleasanton
>
CITY CLERK
>
AGENDA PACKETS
>
2019
>
100119
>
07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/1/2019 9:08:30 AM
Creation date
9/24/2019 3:44:31 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
AGENDA REPORT
DOCUMENT DATE
10/1/2019
DESTRUCT DATE
15Y
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
55
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
accordance with appropriate nationally recognized industry standards and practices, if any. <br />Appropriate remedial action shall be immediately undertaken when leaks are detected. <br />20.24.430 CFC Section 6004.1.15 added —Inert pas purse system. <br />Section 6004.1.15 is added to read: <br />6004.1.15 Inert pas purge system. Gas systems shall be provided with dedicated inert pas <br />purge systems. A dedicated inert pas purge system maV be used to purge more than one pas <br />provided the gases are compatible. Purge pas systems inside buildings shall be located in an <br />approved pas cabinet unless the system operates by vacuum demand. <br />Exception: Refrigeration systems. <br />20.24.440 CFC Section 6004.1.16 added —Seismic shutoff valve. <br />Section 6004.1.16 is added to read: <br />6004.1.16 Seismic shutoff valve. An automatic seismic shut-off valve, which is of a fail-safe to <br />close design, shall be provided to shutoff the supply of highly toxic, toxic and moderately toxic <br />gases with an LC50 less than 3,000 parts per million upon a seismic event within 5 seconds of a <br />horizontal sinusoidal oscillation having a peak acceleration of 0.3G (1.47m/sect) and a period of <br />0.4 seconds. <br />20.24.450 CFC Section 6004.1.17 added —Fittings and connections. <br />Section 6004.1.17 is added to read: <br />6004.1.17 Fittings and connections. Fittings and connections shall be located in a pas cabinet, <br />exhausted enclosure, gas room or exhausted valve manifold box. <br />Exception: Welded connections. <br />20.24.460 CFC Section 6004.2 amended —Indoor storage and use. <br />Section 6004.2 is hereby amended to read: <br />6004.2 Indoor storage and use amended. The indoor storage or use of highly toxic, toxic and <br />moderately toxic compressed gases shall be in accordance with Sections 6004.2.1 through <br />6004.2.2.10.4. <br />20.24.470 CFC Section 6004.2.1 amended —Applicability. <br />Section 6004.2.1 is hereby amended to read: <br />6004.2.1 Applicability. The applicability of regulations governing the indoor storage and use of <br />highly toxic, toxic and moderately toxic compressed gases shall be in accordance with Sections <br />6004.2.1.1 through 6004.2.1.5. <br />20.24.480 CFC Section 6004.2.1.1 amended —Quantities not exceeding the maximum <br />allowable quantity per control area. <br />Section 6004.2.1.1 is hereby amended to read: <br />Page 36 of 52 <br />
The URL can be used to link to this page
Your browser does not support the video tag.