Section 903 of the California Building Code � 201 � Edition, (24 C.C.R. Part 2), and including <br />by reference the International Building Code, 2C�1-5 20 I _Edition is amended to read as shown in <br />section 903 of the Pleasanton Fire Code (PMC Chapter 20.24). <br />20.08.050 CBC Section 904 amended —Alternative Automatic Fire -Extinguishing <br />Systems. <br />Section 904 of the California Building Code ?81-� 2019 Edition, (24 C.C.R. Part 2), and including <br />by reference the International Building Code, �5 2018 Edition is amended to read as shown in <br />section 904 of the Pleasanton Fire Code (PMC Chapter 20.24). <br />20.08.060 CBC Section 1505 amended —Fire Classification. <br />Table 1505.1 Minimum Roof Coverings Classification is deleted, and Section 1505.1 is amended <br />to add the following paragraph to read as follows: <br />1505.1 General. Roof coverings shall h� firo ro+�rrl�n+ have a minimum Class B or higher <br />resistance ratinc for all buildings regardless of type of construction. <br />20.08.070 CBC Section 1705.3 amended —Concrete Construction. <br />Section 1705.3 Exception 1 is amended to read as follows: <br />1705.3 Concrete Construction. The special inspections and verifications for concrete <br />construction shall be as required by this section and Table 1705.3. <br />Exception: Special inspections shall not be required for isolated spread concrete footings of <br />buildings three stories or less above grade plane that are fully supported on earth or rock, <br />where the structural design of the footing is based on a specified compressive strength, f'�, no <br />greater than 2,500 pound per square inch (psi) (17.2 Mpa). <br />20.08.080 <br />Page 12 of 52 <br />
The URL can be used to link to this page
Your browser does not support the video tag.