Laserfiche WebLink
Ordinance No. 2181 <br /> Page 19 of 25 <br /> responsible for the excavation, or to his/her authorized representative. A similar <br /> note shall appear on the improvement plans. <br /> CODE REQUIREMENTS <br /> (Applicants/Developers are responsible for complying with all applicable Federal, State <br /> and City codes and regulations regardless of whether or not the requirements are part <br /> of this list. The following items are provided for the purpose of highlighting key <br /> requirements.) <br /> Livermore-Pleasanton Fire Department (LPFD) <br /> 94. All construction shall conform to the requirements of the California Fire Code <br /> currently in effect, City of Pleasanton Building and Safety Division and City of <br /> Pleasanton Ordinance 2153. All required permits shall be obtained. <br /> 95. Automatic fire sprinklers shall be installed in all occupancies in accordance with <br /> City of Pleasanton Ordinance 2153. Installations shall conform to NFPA <br /> Pamphlet 13. <br /> 96. Fire alarm system shall be provided and installed in accordance with the CFC <br /> currently in effect, the City of Pleasanton Ordinance 2153 and 2002 NFPA 72 - <br /> National Fire Alarm Code. Notification appliances and manual fire alarm boxes <br /> shall be provided in all areas consistent with the definition of a notification zone <br /> (notification zones coincide with the smoke and fire zones of a building). Shop <br /> drawings shall be submitted for permit issuance in compliance with the CFC <br /> currently in effect. <br /> 97. City of Pleasanton Ordinance 2153 requires that all new occupancies be <br /> provided with an approved key box from the Knox Company as specified by the <br /> Fire Department. The applicant is responsible for obtaining approval for location <br /> and the number of boxes from the Fire Prevention Bureau. Information and <br /> application for Knox is available through their website or the Fire Prevention <br /> Bureau. Occupant shall be responsible for providing tenant space building <br /> access keys for insertion into the Knox Box prior to final inspection by the Fire <br /> Department. Keys shall have permanent marked tags identifying address and/or <br /> specific doors/areas accessible with said key. <br /> 98. Underground fire mains, fire hydrants and control valves shall be installed in <br /> conformance with the most recently adopted edition of NFPA Pamphlet 24, <br /> "Outside Protection." <br /> • Fire flow and duration shall be provided in accordance with 2016 CFC <br /> Appendix B. <br /> • The underground pipeline contractor shall submit a minimum of three (3) sets <br /> of installation drawings to the Fire Department, Fire Prevention Bureau. The <br />