EXHIBIT A <br /> Building and Safety Division <br /> 73. The project developer shall submit a building survey and/or record of survey and a site <br /> development plan in accordance with the provisions of Chapter 18.68 of the Municipal <br /> Code of the City of Pleasanton. These plans shall be approved by the Chief Building and <br /> Safety Official prior to the building permit issuance. The site development plan shall <br /> include all required information to design and construct site, grading, paving, drainage, <br /> and utilities. <br /> 74. The project developer shall post address numerals on the building so as to be plainly <br /> visible from all adjoining streets or driveways during both daylight and night time hours. <br /> 75. The building covered by this approval shall be designed and constructed to meet Title 24 <br /> state energy requirements. <br /> 76. All building and/or structural plans must comply with all codes and ordinances in effect <br /> before the Building and Safety Division will issue permits. <br /> Livermore Pleasanton Fire Department(LPFD) <br /> 77. All construction shall conform to the requirements of the California Fire Code currently in <br /> effect, City of Pleasanton Building and Safety Division and City of Pleasanton Ordinance <br /> 2153. All required permits shall be obtained. <br /> 78. Automatic fire sprinklers shall be installed in all occupancies in accordance with City of <br /> Pleasanton Ordinance 2153. Installations shall conform to NFPA Pamphlet 13. <br /> 79. Fire alarm system shall be provided and installed in accordance with the CFC currently <br /> in effect, the City of Pleasanton Ordinance 2153 and 2002 NFPA 72 - National Fire <br /> Alarm Code. Notification appliances and manual fire alarm boxes shall be provided in all <br /> areas consistent with the definition of a notification zone (notification zones coincide with <br /> the smoke and fire zones of a building). Shop drawings shall be submitted for permit <br /> issuance in compliance with the CFC currently in effect. <br /> 80. City of Pleasanton Ordinance 2153 requires that all new occupancies be provided with <br /> an approved key box from the Knox Company as specified by the Fire Department. The <br /> applicant is responsible for obtaining approval for location and the number of boxes from <br /> the Fire Prevention Bureau. Information and application for Knox is available through <br /> their website or the Fire Prevention Bureau. Occupant shall be responsible for providing <br /> tenant space building access keys for insertion into the Knox Box prior to final inspection <br /> by the Fire Department. Keys shall have permanent marked tags identifying address <br /> and/or specific doors/areas accessible with said key. <br /> 81. Underground fire mains, fire hydrants and control valves shall be installed in <br /> conformance with the most recently adopted edition of NFPA Pamphlet 24, "Outside <br /> Protection." <br /> • Fire flow and duration shall be provided in accordance with 2016 CFC Appendix B. <br /> • The underground pipeline contractor shall submit a minimum of three (3) sets of <br /> installation drawings to the Fire Department, Fire Prevention Bureau. The plans shall <br /> have the contractor's wet stamp indicating the California contractor license type, <br /> Page 11 of 16 <br />