Laserfiche WebLink
18. The new apartment and community building shall be constructed to allow for future <br />installation of a Photovoltaic (PV) system and solar water heating systems. The project <br />applicant/developer shall comply with the following requirements for making the <br />proposed residential units photovoltaic -ready and solar -water -heating -ready: <br />a. Electrical conduit and cable pull strings shall be installed from the roof/attic area to <br />the building's main electrical panels; <br />b. An area shall be provided near the electrical panel for the installation of an <br />"inverter" required to convert the direct current output from the photovoltaic panels <br />to alternating current; <br />c. Engineer the roof trusses to handle an additional load as determined by a <br />structural engineer to accommodate the additional weight of a prototypical <br />photovoltaic system beyond that anticipated for roofing; <br />d. Plumbing shall be installed for solar -water heating; and <br />e. Space shall be provided for a solar -water -heating tank. <br />These measures shall be shown on the building permit plan set submitted to the Director <br />of Community Development for review and approval before issuance of the first building <br />permit. <br />19. The State of California's Green Building Standards Code, "CALGreen," shall apply, if <br />applicable. <br />Building and Safety Division <br />20. Unless otherwise approved by the Director or Community Development, all units, <br />including those otherwise required to be adaptable, shall provide the following features: <br />a. Pre -wire for both audible and visual capability of doorbell within unit. <br />b. Balcony/patio floor level not more than one-half inch lower than floor level within <br />the unit at doorway. <br />c. Windows considered suitable for viewing shall have a 36 -inch maximum sill height <br />above finish floor. <br />d. 44 -inch minimum hallway width and 32 -inch minimum clear door opening width for <br />all doorways within units (baseboard may encroach into the minimum hallway <br />width). <br />e. Lever -type handles on all doors. <br />f. An 18 -inch minimum clear floor space beside door on pull side at the latch jamb. <br />g. All receptacle or other wall outlets, 18 -inch minimum height to bottom of outlet box <br />above finish floor. <br />h. Rocker type Tight switches installed 44 to 48 inches to top of outlet box above finish <br />floor, and thermostats 48 inches maximum height to all operating buttons or <br />features. <br />i. Variable height (28 to 42 inches above finish floor) work surfaces such as cutting <br />boards, countertops, sinks, and/or cooktops in kitchens. A minimum of two 15 -inch <br />wide cutting boards at variable heights may satisfy this requirement. <br />j. Loop handle pulls on drawers and cabinet doors or touch hardware instead of <br />knobs. <br />k. Full -extension pull-out drawers, shelves and racks in base cabinets. <br />Page 3 of 16 <br />