Laserfiche WebLink
STONERIDGE DRIVE SPECIFIC PLAN AMENDMENT/STAPLES RANCH PROJECT <br />MITIGATION MONITORING AND REPORTING PLAN [May 2010] <br />Mitigation Measures/Improvement Measures <br />Municipal Airport consistent with Business and Professions Code Section <br />11010 and Civil Code Sections 1102.6, 1103.4, and 1353. <br />Noise <br />NO -I. ]Provide exterior -to -interior noise reduction features for <br />residential, retail, and commercial structures to meet City interior noise <br />level standards. Prior to the City's issuing building permits, the senior <br />continuing care community, auto mall, and commercial developers shall <br />submit to the City noise analyses prepared by a qualified acoustical <br />consultant that demonstrate that all structures will meet City interior noise <br />level standards. Commercial and office uses will need to meet the City <br />standard of 45 dBA peak hour Leq that would allow the conduct of <br />normal business activities inside these facilities. All proposed structures <br />where people will reside will need to be below the City's interior noise <br />level standard of 45 dBA Ldn. Noise reduction features may include, but <br />are not limited to, building siting, upgraded. insulation, sound -rated <br />windows and doors, sound -rated exterior wall assemblies, and acoustical <br />caulking. At the senior continuing care community if exterior -to -interior <br />noise reduction features for a unit where people will sleep require <br />inoperable or closed windows to meet the noise standard, an energy <br />efficient HVAC system meeting California Building Code requirements <br />must be provided. <br />NO -1.2 Provide exterior -to -interior noise reduction features to meet <br />single -event noise level standards Prior to the City's issuing <br />building permits, the developer of the senior continuing care community <br />shall submit to the City a noise analysis prepared by a qualified acoustical <br />consultant that demonstrates that all structures where people will sleep <br />and the health care facility can meet the City standard for single -event <br />noise levels, i.e., the maximum sound levels (L.,o would be below 50 <br />Monitoring Action <br />Verify inclusion of <br />exterior -to -interior <br />noise reduction features <br />to meet City standards <br />in construction plans <br />and specifications; field <br />inspections. <br />Verify inclusion of <br />exterior -to -interior <br />noise reduction features <br />to meet single event <br />noise level standards in <br />construction plans and <br />specifications; field <br />inspections. <br />26 <br />Responsibility''''"'''" <br />Verification: City of <br />Pleasanton Planning <br />Division and Building <br />and Safety Division. <br />Implementation: <br />Project Developers. <br />Field inspections <br />during construction: <br />City of Pleasanton <br />Building and Safety <br />Division. <br />Verification: City of <br />Pleasanton Planning <br />Division and Building <br />and Safety Division. <br />Implementation: <br />Project Developer for <br />the senior continuing. <br />Date Completed/ <br />Timing Signature <br />Prior to issuance <br />of a Building Signature <br />Permit. <br />Title <br />Date <br />Field inspections: <br />Prior to <br />occupancy. <br />Verification: Prior <br />to issuance of a Signature <br />Building Permit. <br />Title <br />Date <br />